| Literature DB >> 6695361 |
O Vesterqvist, K Gréen, F H Lincoln, O K Sebek.
Abstract
Tetradeuterated 2,3-dinor-thromboxane B2 (2,3-dinor-TxB2) of high isotopic purity was prepared. This compound was used as internal standard in the development of a method for quantitation of 2,3-dinor-TxB2 in human urine based on gas chromatography--mass spectrometry with multiple ion detection. The accuracy of the method is about +/- 5% at the levels encountered when urine from normal healthy individuals was analyzed. The daily urinary excretion of 2,3-dinor-TxB2 in twenty normal healthy males and females was 457 +/- 210 (mean +/- SD) and 444 +/- 160 (mean +/- SD) ng/24 hrs respectively. The diurnal and day-to-day variations were found to be relatively small.Entities:
Mesh:
Substances:
Year: 1984 PMID: 6695361 DOI: 10.1016/0049-3848(84)90153-1
Source DB: PubMed Journal: Thromb Res ISSN: 0049-3848 Impact factor: 3.944