Literature DB >> 6694090

Quantitative determination of the stabilizers octanoic acid and N-acetyl-DL-tryptophan in human albumin products.

M W Yu, J S Finlayson.   

Abstract

Methods were developed for the determination of octanoic acid and N-acetyl-DL-tryptophan, which are used as stabilizers in the human blood-derived therapeutic products normal serum albumin and plasma protein fraction. The method for octanoic acid uses GC; quantitation is achieved using heptanoic acid as the internal standard. The method for N-acetyl-DL-tryptophan is based on UV spectrophotometry of the acid-soluble fraction remaining after precipitation of the protein (epsilon 280 for N-acetyl-DL-tryptophan, 5250). The coefficient of variation for replicate determinations of octanoic acid averaged 3.9% (range 2.1-5.5%); that of N-acetyl-DL-tryptophan averaged 1.9% (range 0.5-4.0%). Use of these methods for the analysis of 138 lots of commercial products for octanoic acid and 159 lots for N-acetyl-DL-tryptophan showed that the stabilizer contents of 132 and 158 of these lots, respectively, were within 20% of the value indicated on the product label.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6694090     DOI: 10.1002/jps.2600730122

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  5 in total

1.  Composition of protein supplements used for human embryo culture.

Authors:  Dean E Morbeck; Melissa Paczkowski; Jolene R Fredrickson; Rebecca L Krisher; Heather S Hoff; Nikola A Baumann; Thomas Moyer; Dietrich Matern
Journal:  J Assist Reprod Genet       Date:  2014-09-27       Impact factor: 3.412

Review 2.  Human albumin solution for patients with cirrhosis and acute on chronic liver failure: Beyond simple volume expansion.

Authors:  Christopher Valerio; Eleni Theocharidou; Andrew Davenport; Banwari Agarwal
Journal:  World J Hepatol       Date:  2016-03-08

3.  Interaction between various polymerized human albumins and hepatitis B surface antigen.

Authors:  M W Yu; J S Finlayson; J W Shih
Journal:  J Virol       Date:  1985-09       Impact factor: 5.103

4.  The impact of the protein stabilizer octanoic acid on embryonic development and fetal growth in a murine model.

Authors:  Jolene Fredrickson; Rebecca Krisher; Dean E Morbeck
Journal:  J Assist Reprod Genet       Date:  2015-09-05       Impact factor: 3.412

5.  Development of Improved High-Performance Liquid Chromatography Method for the Determination of Residual Caprylic Acid in Formulations of Human Immunoglobulins.

Authors:  Adela Štimac; Tihana Kurtović; Nediljko Pavlović; Beata Halassy
Journal:  Molecules       Date:  2022-03-03       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.