Difficulty of extraction of chronically implanted tined ventricular endocardial leads.

N P Madigan, J J Curtis, J F Sanfelippo, T J Murphy.   

Abstract

The dislodgment rate of permanent pacing ventricular and atrial endocardial leads has significantly decreased with the incorporation of tines as a fixation device. In contrast, transvenous manual extraction of chronically implanted endocardial leads is, at times, clinically indicated, particularly when pacemaker system infection is present. The success rate of such extraction attempts for ventricular endocardial leads over the past 5 years was reviewed. Extraction was usually successful (six of seven attempts) in patients with silicone rubber nontined (or short-tined) older ventricular endocardial leads (Group A). However, in patients with newer urethane long-tined ventricular endocardial leads (Group B), extraction was unsuccessful in three of four attempts. Because of entrapment of the distal electrode tip in the right ventricular apex, manual traction of these leads resulted in permanent conductor material stretching with resultant urethane insulator material breakage in the region of the joints with proximal and distal electrodes. The one successful extraction in Group B was technically difficult and appeared to create a significant risk of intracardiac lead separation. This experience indicates that with improved pacemaker lead design decreased lead dislodgment has been obtained at the cost of increased difficulty of ventricular endocardial lead extraction. Such difficulty should be anticipated when a clinical decision is made to attempt to extract the new urethane long-tined ventricular leads.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6693644     DOI: 10.1016/s0735-1097(84)80248-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  [Removal of the endocardial pacemaker leads--experience with 16 leads in 10 patients].

Authors:  S Hasegawa; T Morimoto; N Matsuyama; J Okamoto; Y Sawada; K Kondo; K Asada; S Sasaki
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-05

Review 2.  Endovascular extraction techniques for pacemaker and ICD lead extraction: Part 1.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-04       Impact factor: 2.380

3.  Endocardial and epicardial steroid lead pacing in the neonatal and paediatric age group.

Authors:  F Udink ten Cate; J Breur; N Boramanand; J Crosson; A Friedman; J Brenner; E Meijboom; N Sreeram
Journal:  Heart       Date:  2002-10       Impact factor: 5.994

4.  Use of laser to extract unwanted pacemaker leads.

Authors:  G Rao; P Flaherty
Journal:  Tex Heart Inst J       Date:  1989
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.