Literature DB >> 6692271

Needle aspiration of the breast.

W J Frable.   

Abstract

Using a 20- or 22-gauge needle and a 20.0 ml syringe attached to a commercially available syringe pistol, the author performed 853 aspiration biopsies of palpable breast masses during the 9-year period 1974 through 1982. There were 269 diagnoses of breast cancer, 42 suspected cases of cancer, and 496 aspirates reported as benign tumor, inflammation, or another non-neoplastic diagnosis. Twenty-seven cases of carcinoma were not diagnosed from the aspiration biopsy sample. There was one false-positive diagnosis of carcinoma in a patient whose tumor was a cystosarcoma phylloides, benign variant. Forty-six aspirates were considered unsatisfactory, usually because of an insufficient cellular sample. Sensitivity for the diagnosis of breast cancer was 89.0%, while specificity for the absence of breast cancer was 97.0%. Only 13 cases in the group reported as suspicious for carcinoma were proven not to be breast cancer after excisional biopsy and histologic study. The procedure is free of complications, convenient, and cost effective. It provides for evaluation of the patient who has breast cancer on an outpatient basis as well as a full discussion of treatment options prior to intervention.

Entities:  

Mesh:

Year:  1984        PMID: 6692271     DOI: 10.1002/1097-0142(19840201)53:3+<671::aid-cncr2820531313>3.0.co;2-a

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  7 in total

Review 1.  Percutaneous biopsies of the breast: state of the art.

Authors:  B D Fornage
Journal:  Cardiovasc Intervent Radiol       Date:  1991 Jan-Feb       Impact factor: 2.740

2.  Complications of mastectomy and their relationship to biopsy technique.

Authors:  K A Lipshy; J P Neifeld; R M Boyle; W J Frable; S Ronan; P Lotfi; H D Bear; J S Horsley; W Lawrence
Journal:  Ann Surg Oncol       Date:  1996-05       Impact factor: 5.344

3.  Cost-effectiveness of fine needle biopsy of the breast.

Authors:  D R Lannin; J F Silverman; C Walker; W J Pories
Journal:  Ann Surg       Date:  1986-05       Impact factor: 12.969

4.  Adequate reimbursement is crucial to support cost-effective rapid on-site cytopathology evaluations.

Authors:  Mousa A Al-Abbadi; Leonard I Bloom; Lisa A Fatheree; Lori A Haack; Gerald Minkowitz; David C Wilbur; Marshall R Austin
Journal:  Cytojournal       Date:  2010-10-18       Impact factor: 2.091

5.  Pneumothorax following breast aspiration.

Authors:  L H Stewart
Journal:  Ulster Med J       Date:  1990-10

6.  Efficacy of Modified Masood Scoring System (MMSS) in Cytological Diagnosis of Breast Lesions.

Authors:  Justina William; Kanwal Masih; Uma Pradhan; Jasneet Kaur; Upinder Singh; Gulshanjit Singh
Journal:  Cureus       Date:  2022-02-16

7.  Comparison of specimen adequacy in fine-needle aspiration biopsies performed by surgeons and pathologists.

Authors:  Yusef M Al-Marzooq; Rajan Chopra; Ahmed T Al-Bahrani; Mohammad Younis; Abdulrahman S Al-Mulhim; Mohammed I Al-Mommatten
Journal:  Ann Saudi Med       Date:  2004 Mar-Apr       Impact factor: 1.526

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.