Literature DB >> 6691264

Two-dimensional echocardiographic determination of aortic and pulmonary artery sizes from infancy to adulthood in normal subjects.

A R Snider, M A Enderlein, D F Teitel, R P Juster.   

Abstract

The aorta, right pulmonary artery and pulmonary trunk were measured from the 2-dimensional echocardiogram (2-D echo) of 110 normal subjects aged 1 day to 18 years. The vessel diameters were measured from the parasternal short-axis view, the suprasternal long-axis view and the suprasternal short-axis view. Measurements were made at end-systole and at end-diastole and in both an axial and lateral direction where possible. When analyzed with respect to body surface area (BSA), the echocardiographic measurements were linearly related to the square root of the BSA, and there was inequality of variance around the relation. To establish a range of normal values for each vessel dimension, a weighted regression analysis was used to produce estimates of the regression line and a set of tolerance intervals. The systolic vessel dimension was larger than the diastolic vessel dimension and the measurement of a vessel in an axial direction was larger than the measurement of the same vessel in a lateral direction. In general, when a vessel was measured in several views, the largest diameter was obtained using the view that imaged the vessel in cross section. These data on normal values for the echocardiographic measurement of the aorta and pulmonary arteries at different BSAs should be useful for identifying patients with abnormalities in arterial size and for the serial assessment of arterial size in children who have undergone surgical or medical therapy.

Entities:  

Mesh:

Year:  1984        PMID: 6691264     DOI: 10.1016/0002-9149(84)90715-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  22 in total

1.  Geometry and dimensions of the pulmonary artery bifurcation in children and adolescents: assessment in vivo by contrast-enhanced MR-angiography.

Authors:  Zita Knobel; Christian J Kellenberger; Thomas Kaiser; Manuela Albisetti; Eva Bergsträsser; Emanuela R Valsangiacomo Buechel
Journal:  Int J Cardiovasc Imaging       Date:  2010-07-21       Impact factor: 2.357

2.  Two-dimensional echocardiographic valve measurements in healthy children: gender-specific differences.

Authors:  M V Zilberman; P R Khoury; R T Kimball
Journal:  Pediatr Cardiol       Date:  2005 Jul-Aug       Impact factor: 1.655

3.  Doppler-derived mean aortic flow velocity in children: an alternative to cardiac index.

Authors:  M D Seear; L D'Orsogna; G G Sandor; E de Souza; R Popov
Journal:  Pediatr Cardiol       Date:  1991-10       Impact factor: 1.655

4.  4D-MR flow analysis in patients after repair for tetralogy of Fallot.

Authors:  J Geiger; M Markl; B Jung; J Grohmann; B Stiller; M Langer; R Arnold
Journal:  Eur Radiol       Date:  2011-03-29       Impact factor: 5.315

5.  Relationship of Echocardiographic Z Scores Adjusted for Body Surface Area to Age, Sex, Race, and Ethnicity: The Pediatric Heart Network Normal Echocardiogram Database.

Authors:  Leo Lopez; Steven Colan; Mario Stylianou; Suzanne Granger; Felicia Trachtenberg; Peter Frommelt; Gail Pearson; Joseph Camarda; James Cnota; Meryl Cohen; Andreea Dragulescu; Michele Frommelt; Olukayode Garuba; Tiffanie Johnson; Wyman Lai; Joseph Mahgerefteh; Ricardo Pignatelli; Ashwin Prakash; Ritu Sachdeva; Brian Soriano; Jonathan Soslow; Christopher Spurney; Shubhika Srivastava; Carolyn Taylor; Poonam Thankavel; Mary van der Velde; LuAnn Minich
Journal:  Circ Cardiovasc Imaging       Date:  2017-11       Impact factor: 7.792

6.  Use of oversized injectable valves in growing children for total repair of right ventricular outflow tract anomalies (preliminary results).

Authors:  Luca Deorsola; Pietro Angelo Abbruzzese
Journal:  Tex Heart Inst J       Date:  2014-08-01

7.  Aortic aneurysmal disease and cutis laxa caused by defects in the elastin gene.

Authors:  Z Szabo; M W Crepeau; A L Mitchell; M J Stephan; R A Puntel; K Yin Loke; R C Kirk; Z Urban
Journal:  J Med Genet       Date:  2005-08-05       Impact factor: 6.318

8.  Cardiac Valve Annulus Diameters in Extremely Preterm Infants: A Cross-Sectional Echocardiographic Study.

Authors:  Allard E van Ark; Mirella C Molenschot; Maria H Wesseling; Willem B de Vries; Jan L M Strengers; Arthur Adams; Johannes M P J Breur
Journal:  Neonatology       Date:  2018-06-25       Impact factor: 4.035

9.  Natural history of innocent heart murmurs in newborn babies: controlled echocardiographic study.

Authors:  R Arlettaz; N Archer; A R Wilkinson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-05       Impact factor: 5.747

10.  Descending aortic blood flow velocity as a noninvasive measure of cardiac output in children.

Authors:  M Seear; S Webber; J Leblanc
Journal:  Pediatr Cardiol       Date:  1994 Jul-Aug       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.