Literature DB >> 6690950

Clinical use of the total artificial heart.

W C DeVries, J L Anderson, L D Joyce, F L Anderson, E H Hammond, R K Jarvik, W J Kolff.   

Abstract

We report here our first experience with the use of a total artificial heart in a human being. The heart was developed at the University of Utah, and the patient was a 61-year-old man with chronic congestive heart failure due to primary cardiomyopathy, who also had chronic obstructive pulmonary disease. Except for dysfunction of the prosthetic mitral valve, which required replacement of the left-heart prosthesis on the 13th postoperative day, the artificial heart functioned well for the entire postoperative course of 112 days. The mean blood pressure was 84 +/- 8 mm Hg, and cardiac output was generally maintained at 6.7 +/- 0.8 liters per minute for the right heart and 7.5 +/- 0.8 for the left, resulting in postoperative diuresis and relief of congestive failure. The postoperative course was complicated by recurrent pulmonary insufficiency, several episodes of acute renal failure, episodes of fever of unidentified cause (necessitating multiple courses of antibiotics), hemorrhagic complications of anticoagulation, and one generalized seizure of uncertain cause. On the 92nd postoperative day, the patient had diarrhea and vomiting, leading to aspiration pneumonia and sepsis. Death occurred on the 112th day, preceded by progressive renal failure and refractory hypotension, despite maintenance of cardiac output. Autopsy revealed extensive pseudomembranous colitis, acute tubular necrosis, peritoneal and pleural effusion, centrilobular emphysema, and chronic bronchitis with fibrosis and bronchiectasis. The artificial heart system was intact and uninvolved by thrombosis or infectious processes. This experience should encourage further clinical trials with the artificial heart, but we emphasize that the procedure is still highly experimental. Further experience, development, and discussion will be required before more general application of the device can be recommended.

Entities:  

Mesh:

Year:  1984        PMID: 6690950     DOI: 10.1056/NEJM198402023100501

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  34 in total

1.  Cardiac surgery: a century of progress.

Authors:  Allen B Weisse
Journal:  Tex Heart Inst J       Date:  2011

Review 2.  Ventricular assist devices: pharmacological aspects of a mechanical therapy.

Authors:  O Wever-Pinzon; J Stehlik; A G Kfoury; J V Terrovitis; N A Diakos; C Charitos; D Y Li; S G Drakos
Journal:  Pharmacol Ther       Date:  2012-01-16       Impact factor: 12.310

3.  Stamps in cardiology. Artificial heart.

Authors:  T Treasure; M K Davies; A Hollman
Journal:  Heart       Date:  2006-05       Impact factor: 5.994

4.  A noninvasive method of estimating mean pulmonary artery pressure in the pneumatic total artificial heart.

Authors:  M J Vonesh; R C Cork; K C Mylrea
Journal:  J Clin Monit       Date:  1991-10

5.  Saving lives, not sacrificing them: the inevitable clash between medical research and the protection of medical subjects.

Authors:  Allen B Weisse
Journal:  Proc (Bayl Univ Med Cent)       Date:  2013-07

6.  Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system.

Authors:  O H Frazier; E A Rose; P McCarthy; N A Burton; A Tector; H Levin; H L Kayne; V L Poirier; K A Dasse
Journal:  Ann Surg       Date:  1995-09       Impact factor: 12.969

Review 7.  Mechanical circulatory support.

Authors:  Deborah J Kozik; Mark D Plunkett
Journal:  Organogenesis       Date:  2011-01-01       Impact factor: 2.500

Review 8.  Total artificial hearts: past, present, and future.

Authors:  William E Cohn; Daniel L Timms; O H Frazier
Journal:  Nat Rev Cardiol       Date:  2015-06-02       Impact factor: 32.419

Review 9.  Devices in the management of advanced, chronic heart failure.

Authors:  William T Abraham; Sakima A Smith
Journal:  Nat Rev Cardiol       Date:  2012-12-11       Impact factor: 32.419

10.  Cardiac transplantation. Emerging from an experiment to a service.

Authors:  B P Griffith; R L Hardesty; A Trento; R L Kormos; H T Bahnson
Journal:  Ann Surg       Date:  1986-09       Impact factor: 12.969

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.