Literature DB >> 6690851

Results and complications with the Omniscience prosthesis.

G Rábago, J Martinell, J Fraile, I G Andrade, R Montenegro.   

Abstract

A clinical trial with the Omniscience heart valve was conducted from June, 1980, until May, 1981. In this period 166 patients underwent heart valve replacement: mitral valve replacement (MVR) 70 patients, aortic valve replacement (AVR) 37, and combined mitral-aortic valve replacement (M/AVR) 59 patients. There were 20 hospital deaths, for a mortality of 12%. Total follow-up was 226 patient-years (range 6 to 28 months, mean 18 months). There were eight late deaths (MVR 4.6%, AVR 3.1%, and M/AVR 8.1%). All patients were taking oral anticoagulants. The incidence of valve-related complications (expressed as events per 100 patient-years) was as follows: Systemic embolism--MVR 2, AVR 4.7, and M/AVR 2.5; and anticoagulant complications--MVR 1.9, AVR 2.3, and M/AVR 0. The incidence of valvular dysfunction (expressed as events per 100 patient-years) was as follows: valvular thrombosis--MVR 4.8, AVR 0, and M/AVR 1.2; perivalvular leakage--MVR 1.9, AVR 2.3, and M/AVR 2.5; and infective endocarditis--MVR 0.96, AVR 0, and M/AVR 1.2. The actuarial probability of being free of valvular dysfunction 30 months postoperatively is 73% for the MVR group, 90% for the AVR group, and 71% for the M/AVR group. Despite a short follow-up, the incidence of valvular dysfunction has been significant. For this reason, we have discontinued using these prostheses for heart valve replacement.

Entities:  

Mesh:

Year:  1984        PMID: 6690851

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

Review 1.  A 44-year experience of prosthetic heart valve implantation at Niigata University Hospital.

Authors:  Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2012-04-24       Impact factor: 1.731

2.  Intermittently stuck occluder: case report of an unusual complication with the use of an aortic Omniscience prosthesis.

Authors:  S Nawa; S Ohsumi; K Kurozumi; H Izumoto; Y Nakayama; M Shigenobu; E Sugawara; Y Senoo; S Teramoto
Journal:  Heart Vessels       Date:  1987       Impact factor: 2.037

3.  The necessity of reoperation for patients with Bjork-Shiley, St Jude Medical, Hancock and Carpentier-Edwards prostheses.

Authors:  Y Morishita; H Toyohira; T Yuda; Y Umebayashi; H Saigenji; M Hashiguchi; K Uehara; A Taira
Journal:  Jpn J Surg       Date:  1990-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.