Literature DB >> 6664820

Do evacuated blood collection tubes interfere with therapeutic drug monitoring?

R Janknegt, J J Lohman, P M Hooymans, F W Merkus.   

Abstract

The influence of various brands of evacuated blood collection systems (the old type, red stoppered Vacutainer; the new type, blue stoppered Vacutainer; Monoject and Venoject) on therapeutic drug monitoring was investigated. No interferences were found in the assay of ethosuximide, phenobarbital, phenytoin, valproic acid, digitoxin, digoxin, procainamide, gentamicin and theophylline. Using Monoject and old type Vacutainer tubes, lower levels were found in the disopyramide assay: 91.3 +/- 4.6% (p less than 0.05) and 91.7 +/- 7.0% (not significant) respectively, and in the quinidine assay: 82.8 +/- 6.7% (p less than 0.02) and 83.9 +/- 4.4% (p less than 0.001) respectively as compared with glass tubes. In the carbamazepine assay a decrease was found in the Monoject tubes only: 93.7 +/- 1.7% (p less than 0.01). The stoppers of Monoject tubes and the old type Vacutainer tubes contained the plasticizer tris-(2-butoxyethyl)phosphate (TBEP), which has been shown to be a potent inhibitor of the binding of several drugs to alpha 1-acid glycoprotein. Using the new type Vacutainer and the Venoject, no interferences were found.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6664820     DOI: 10.1007/bf02074856

Source DB:  PubMed          Journal:  Pharm Weekbl Sci        ISSN: 0167-6555


  20 in total

1.  Spuriously low plasma propranolol concentrations resulting from blood collection methods.

Authors:  R H Cotham; D Shand
Journal:  Clin Pharmacol Ther       Date:  1975-11       Impact factor: 6.875

2.  Rapid and sensitive liquid chromatographic determination of carbamazepine suitable for use in monitoring multiple-drug anticonvulsant therapy.

Authors:  H G Westenberg; R A de Zeeuw
Journal:  J Chromatogr       Date:  1976-03-17

3.  Gas-chromatographic micro-scale procedure for theophylline, with use of a nitrogen-sensitive detector.

Authors:  C J Least; G F Johnson; H M Solomon
Journal:  Clin Chem       Date:  1976-06       Impact factor: 8.327

4.  Letter: Reduced binding of quinidine in plasma from Vacutainers.

Authors:  D Fremstad; K Bergerud
Journal:  Clin Pharmacol Ther       Date:  1976-07       Impact factor: 6.875

5.  Ion-pair liquid chromatography of steady-state plasma levels of chlorimipramine and demethylchlorimipramine.

Authors:  B Mellström; G Tybring
Journal:  J Chromatogr       Date:  1977-11-01

Review 6.  Disease-induced changes in the plasma binding of basic drugs.

Authors:  K M Piafsky
Journal:  Clin Pharmacokinet       Date:  1980 May-Jun       Impact factor: 6.447

7.  Simultaneous quantitation of quinidine, procainamide, and N-acetylprocainamide in serum by gas-liquid chromatography with a nitrogen-phosphorus selective detector.

Authors:  K M Kessler; P Ho-Tung; B Steele; J Silver; A Pickoff; S Narayanan; R J Myerburg
Journal:  Clin Chem       Date:  1982-05       Impact factor: 8.327

8.  Simultaneous liquid-chromatographic determination of three antiarrhythmic drugs: disopyramide, lidocaine, and quinidine.

Authors:  J G Flood; G N Bowers; R B McComb
Journal:  Clin Chem       Date:  1980-02       Impact factor: 8.327

9.  Plasma protein binding of basic drugs. I. Selective displacement from alpha 1-acid glycoprotein by tris(2-butoxyethyl) phosphate.

Authors:  O Borgå; K M Piafsky; O G Nilsen
Journal:  Clin Pharmacol Ther       Date:  1977-11       Impact factor: 6.875

10.  Importance of blood-collection tubes in plasma lidocaine determinations.

Authors:  W W Stargel; C R Roe; P A Routledge; D G Shand
Journal:  Clin Chem       Date:  1979-04       Impact factor: 8.327

View more
  1 in total

Review 1.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.