Literature DB >> 6663483

Direct determination of avermectins in plasma at nanogram levels by high-performance liquid chromatography.

J V Pivnichny, J S Shim, L A Zimmerman.   

Abstract

22,23-Dihydroavermectin B1a (I) is determined in animal plasma over the concentration range 5-60 ng/ml by reverse-phase high-performance liquid chromatography (HPLC) with UV photometric detection. Prior to HPLC the sample is isolated by gravity-fed adsorption column chromatography on Florisil. The delta 2 isomer of I (designated as compound III) is used as an internal standard, and the conversion of I to this isomer by base hydrolysis is described. An accuracy of 2 ng/ml (mean deviation) and a precision in the range of 1-3 ng/ml (standard deviation) were observed for the method. The limit of detection is 2 ng/ml based on the background observed for normal cattle plasma. The method is applicable to bioavailability studies of I at usual therapeutic concentrations.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6663483     DOI: 10.1002/jps.2600721219

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  2 in total

1.  Pharmacokinetic studies of ivermectin: effects of formulation.

Authors:  P K Lo; D W Fink; J B Williams; J Blodinger
Journal:  Vet Res Commun       Date:  1985-09       Impact factor: 2.459

Review 2.  Clinical pharmacokinetics of anthelmintic drugs.

Authors:  G Edwards; A M Breckenridge
Journal:  Clin Pharmacokinet       Date:  1988-08       Impact factor: 6.447

  2 in total