Literature DB >> 6661157

Investigation of Frank's vectorcardiographic lead system on homogeneous rabbit torso model.

V R Lolov, R V Lolov.   

Abstract

The applicability of Frank's lead system in experiments on rabbits is studied by using a homogeneous rabbit torso model. The influence of dipole localization on the modules of the lead vectors at the level of 4th, 5th and 6th intercostal spaces is studied. The lead vector modules along the axes X, Y and Z for the level of the dipole are calculated to be equal to 1:0.99:0.92. The maximum angular errors in the planes XY, XZ and YZ are calculated, being for the same level theta yz = -6 degrees 50', theta xy = theta xz = 0 degrees 00'. The authors have reached the conclusion that Frank's system produces good levelling of the lead vector modules and has satisfactory orthogonality on rabbit torso model.

Entities:  

Mesh:

Year:  1983        PMID: 6661157     DOI: 10.1007/bf01907208

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  12 in total

1.  ELECTROCARDIOGRAPHIC LEAD-TENSOR MEASURING SYSTEM.

Authors:  R C ARZBAECHER; D A BRODY
Journal:  IEEE Trans Biomed Eng       Date:  1964 Jan-Apr       Impact factor: 4.538

2.  A COMPARATIVE ANALYSIS OF SEVERAL CORRECTED VECTORCARDIOGRAPHIC LEADS.

Authors:  D A BRODY; R C ARZBAECHER
Journal:  Circulation       Date:  1964-04       Impact factor: 29.690

3.  Lead vectors and transfer impedance.

Authors:  O H SCHMITT
Journal:  Ann N Y Acad Sci       Date:  1957-08-09       Impact factor: 5.691

4.  A theoretical analysis of intracavitary blood mass influence on the heart-lead relationship.

Authors:  D A BRODY
Journal:  Circ Res       Date:  1956-11       Impact factor: 17.367

5.  A new quantitative basis for electrocardiographic theory: the normal QRS complex.

Authors:  E FRANK; C F KAY; G E SEIDEN; R A KEISMAN
Journal:  Circulation       Date:  1955-09       Impact factor: 29.690

6.  The present status of vectorcardiography.

Authors:  O H SCHMITT; E SIMONSON
Journal:  AMA Arch Intern Med       Date:  1955-11

7.  Electrocardiographic mirror pattern studies. I. Experimental validity tests of the dipole hypothesis and of the central terminal theory.

Authors:  O H SCHMITT; R B LEVINE; E SIMONSON
Journal:  Am Heart J       Date:  1953-03       Impact factor: 4.749

8.  HEART-VECTOR AND LEADS. Part II.

Authors:  H C Burger; J B Van Milaan
Journal:  Br Heart J       Date:  1947-07

9.  Effects of torso shape and change of dipole location on ECG and VCG lead vectors in a homogeneous torso model.

Authors:  H Toyoshima; A Ito; J Toyama; K Yamada
Journal:  J Electrocardiol       Date:  1979-07       Impact factor: 1.438

10.  Major VCG systems proposed in the USA.

Authors:  Z Z Zao
Journal:  J Electrocardiol       Date:  1971       Impact factor: 1.438

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.