Literature DB >> 6659004

Paraplegia associated with intraaortic balloon pump counterpulsation.

B M Singh, A E Fass, R W Pooley, R Wallach.   

Abstract

Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hypoxia and arterial dissection.

Entities:  

Mesh:

Year:  1983        PMID: 6659004     DOI: 10.1161/01.str.14.6.983

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  2 in total

Review 1.  Neurologic Complications in the Intensive Care Unit.

Authors:  Clio Rubinos; Sean Ruland
Journal:  Curr Neurol Neurosci Rep       Date:  2016-06       Impact factor: 5.081

2.  Spinal cord infarction during venoarterial-extracorporeal membrane oxygenation support.

Authors:  Loïc Le Guennec; Natalia Shor; Bruno Levy; Guillaume Lebreton; Pascal Leprince; Alain Combes; Didier Dormont; Charles-Edouard Luyt
Journal:  J Artif Organs       Date:  2020-05-30       Impact factor: 1.731