Literature DB >> 6653599

Inability of seven-pinhole myocardial tomography to obtain accurate 201Tl kinetic data.

T J Brady, D D O'Keefe, R D Okada, M A Jacocks, R G Johnson, G A Geffin, D Merrill, H W Strauss, W M Daggett, G M Pohost.   

Abstract

Seven-pinhole myocardial tomography has been reported to enhance the accuracy of thallium-201 (201Tl) studies in detecting patients with coronary artery disease. To determine if this approach can accurately assess regional 201Tl kinetics, 12 dogs with temporary occlusion (mean 15 min) of either the left anterior descending (LAD) (n = 6) or left circumflex (LCX) (n = 6) coronary artery were studied. Thallium-201 was injected and serial 7-pinhole images were acquired during occlusion and following reflow (mean duration 175 min). Time-activity analysis was obtained from normal and ischemic regions of interest in the central pinhole image and the reconstructed tomographic images (TOMO-ROI). Time-activity data from corresponding normal and ischemic regions were also obtained using a circumferential graph program (TOMO-MAX). In addition, regional myocardial 201Tl activity was recorded continuously with a cadmium telluride radiation probe sutured directly to the posterior myocardial wall. Defects in 201Tl distribution with subsequent partial or complete redistribution were present in 11 of 12 central pinhole images and tomographic studies. In the normal and ischemic anterior myocardial segments the percentage change in 201Tl activity in the central pinhole image from occlusion to the end of reflow correlated well with the percentage change in activity for both TOMO-ROI (r = 0.93) and TOMO-MAX (r = 0.85). In the normal posterior segments the percentage change in 201Tl activity in the central pinhole image correlated well with TOMO-ROI (r = 0.98) and TOMO-MAX (r = 0.87).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6653599     DOI: 10.1007/BF00252940

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Thallium-201 for myocardial imaging. Relation of thallium-201 to regional myocardial perfusion.

Authors:  H W Strauss; K Harrison; J K Langan; E Lebowitz; B Pitt
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

2.  Thallium-201 myocardial scintigraphy: a critical comparison of seven-pinhole tomography and conventional planar imaging.

Authors:  H R Rizi; R C Kline; J H Thrall; M C Besozzi; J W Keyes; W L Rogers; J Clare; B Pitt
Journal:  J Nucl Med       Date:  1981-06       Impact factor: 10.057

3.  Seven-pinhole emission tomography with thallium-201 in patients with prior myocardial infarction.

Authors:  J L Ritchie; D L Williams; J H Caldwell; J R Stratton; G D Harp; R A Vogel; G W Hamilton
Journal:  J Nucl Med       Date:  1981-02       Impact factor: 10.057

4.  In vivo simulation of thallium-201 myocardial scintigraphy by seven-pinhole emission tomography.

Authors:  D L Williams; J L Ritchie; G D Harp; J H Caldwell; G W Hamilton
Journal:  J Nucl Med       Date:  1980-09       Impact factor: 10.057

5.  Mechanisms and time course for the disappearance of thallium-201 defects at rest in dogs. Relation of time to peak activity to myocardial blood flow.

Authors:  R D Okada; J A Leppo; H W Strauss; C A Boucher; G M Pohost
Journal:  Am J Cardiol       Date:  1982-03       Impact factor: 2.778

6.  Thallium-201 kinetics in nonischemic canine myocardium.

Authors:  R D Okada; M L Jacobs; W M Daggett; J Leppo; H W Strauss; J B Newell; R Moore; C A Boucher; D O'Keefe; G M Pohost
Journal:  Circulation       Date:  1982-01       Impact factor: 29.690

Review 7.  Thallium redistribution: mechanisms and clinical utility.

Authors:  G M Pohost; N M Alpert; J S Ingwall; H W Strauss
Journal:  Semin Nucl Med       Date:  1980-01       Impact factor: 4.446

8.  Thallium-201 myocardial perfusion scintigraphy: results of standard and multi-pinhole tomographic techniques.

Authors:  R A Vogel; D L Kirch; M T LeFree; J O Rainwater; D P Jensen; P P Steele
Journal:  Am J Cardiol       Date:  1979-04       Impact factor: 2.778

9.  A new method of multiplanar emission tomography using a seven pinhole collimator and an Anger scintillation camera.

Authors:  R A Vogel; D Kirch; M LeFree; P Steele
Journal:  J Nucl Med       Date:  1978-06       Impact factor: 10.057

10.  Differentiation of transiently ischemic from infarcted myocardium by serial imaging after a single dose of thallium-201.

Authors:  G M Pohost; L M Zir; R H Moore; K A McKusick; T E Guiney; G A Beller
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690