Comparative study of home blood glucose monitoring devices: Visidex, Chemstrip bG, Glucometer, and Accu-Chek bG.

S Aziz, Y H Hsiang.   

Abstract

Visidex (Ames Company, Elkhart, Indiana) and Accu-Chek bG (Bio-Dynamics, Boehringer Mannheim, Indianapolis, Indiana), two new devices for determining blood glucose at home, were compared with two older devices, Chemstrip bG (Bio-Dynamics) and Glucometer (Ames Company), and the standard laboratory glucose-oxidase method (Beckman autoanalyzer, Beckman Instruments, Fullerton, California). Laboratory serum glucose values up to 400 mg/dl had excellent overall correlation with Accu-Chek bG (r = 0.974), Glucometer (r = 0.974), Chemstrip bG (r = 0.963), and Visidex (r = 0.955). For glucose values less than or equal to 180 mg/dl, Glucometer had the best correlation (r = 0.921). For glucose values of 181-400 mg/dl, Accu-Chek bG had better correlation (r = 0.907) although Glucometer had closer mean value. Visidex was just as accurate as Chemstrip bG. Although the four devices tested tended to give lower values than the lab method, they are sufficiently accurate to be of clinical use in home monitoring of blood glucose. Meticulous care in running the tests is mandatory for accuracy. Individual differences among the four methods are discussed.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6653308     DOI: 10.2337/diacare.6.6.529

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  5 in total

1.  Does antipsychotic polypharmacy increase the risk for metabolic syndrome?

Authors:  Christoph U Correll; Anne M Frederickson; John M Kane; Peter Manu
Journal:  Schizophr Res       Date:  2006-10-27       Impact factor: 4.939

2.  Self-monitoring of the blood glucose level: potential sources of inaccuracy.

Authors:  B Rasaiah
Journal:  Can Med Assoc J       Date:  1985-06-15       Impact factor: 8.262

Review 3.  Impact of blood glucose monitoring on diabetic control: obstacles and interventions.

Authors:  T Wysocki
Journal:  J Behav Med       Date:  1989-04

4.  Serum gastrin and blood glucose levels during halothane-nitrous oxide anaesthesia and strabismus surgery in children.

Authors:  V F Blanc; P Ruest; G Brisson; J L Jacob
Journal:  Can J Anaesth       Date:  1991-01       Impact factor: 5.063

5.  Blue-yellow vision deficits in patients with diabetes.

Authors:  M Rockett; D Anderle; A N Bessman
Journal:  West J Med       Date:  1987-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.