Literature DB >> 6653042

Measurement of chest wall movement; design, performance and clinical use of a four-channel magnetometer instrument.

C J Griffiths, J J Gilmartin, G J Gibson, A Murray.   

Abstract

A four-channel magnetometer instrument is described. It has been developed to measure changes in diameters of the chest and abdomen during respiration. A linearisation correction allows for the magnetic field strength detected by the receiver being proportional to the inverse cube of the diameter being measured. Diameters and changes in diameter are measured to an accuracy of 4% (1 SD) over the working range (15-50 cm). The effects of non-ideal positioning and extraneous movements of the magnetometer coils, cross-channel interference and the influence of nearby metals are described. With minimal care in positioning the coils, these effects are negligible. The instrument has been in use for one year, assessing chest wall movement in patients with abnormal lung function. Recordings are presented illustrating typical normal and abnormal chest wall movements.

Entities:  

Mesh:

Year:  1983        PMID: 6653042     DOI: 10.1088/0143-0815/4/4/001

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  7 in total

1.  Repeatability of measurements and sources of variability in tests of cardiovascular autonomic function.

Authors:  G P Lawrence; P D Home; A Murray
Journal:  Br Heart J       Date:  1992-08

2.  A video system for investigating breathing disorders during sleep.

Authors:  C J Griffiths; B G Cooper; G J Gibson
Journal:  Thorax       Date:  1991-02       Impact factor: 9.139

3.  Rib cage mechanics after median sternotomy.

Authors:  T J Locke; T L Griffiths; H Mould; G J Gibson
Journal:  Thorax       Date:  1990-06       Impact factor: 9.139

4.  Abnormalities of chest wall motion in patients with chronic airflow obstruction.

Authors:  J J Gilmartin; G J Gibson
Journal:  Thorax       Date:  1984-04       Impact factor: 9.139

5.  Respiratory muscle activity during rapid eye movement (REM) sleep in patients with chronic obstructive pulmonary disease.

Authors:  J E White; M J Drinnan; A J Smithson; C J Griffiths; G J Gibson
Journal:  Thorax       Date:  1995-04       Impact factor: 9.139

6.  Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults.

Authors:  Diliang Chen; Fei Chen; Alan Murray; Dingchang Zheng
Journal:  Biomed Eng Online       Date:  2016-05-10       Impact factor: 2.819

7.  Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement.

Authors:  Dingchang Zheng; Luigi Yuri Di Marco; Alan Murray
Journal:  Med Biol Eng Comput       Date:  2014-03-26       Impact factor: 2.602

  7 in total