Bromocresol purple and the measurement of albumin. Falsely high plasma albumin concentrations eliminated by increased reagent ionic strength.

P G Hill, T N Wells.   

Abstract

This study was undertaken to investigate the extent of the reported discrepancy between serum and plasma albumin concentrations measured by the bromocresol purple (BCP) method. We have shown that plasma albumin concentrations are falsely increased by turbidity due to the precipitation of fibrinogen when plasma is diluted into the BCP reagent. Modification of the BCP buffer (to 0.1M acetate containing 0.15M NaCl, pH 5.5) eliminates the turbidity and thus permits the measurement of albumin in either serum or plasma. Plasma albumin concentrations measured with the modified BCP reagent show excellent correlation with results by an immunoturbidimetric method.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6651190     DOI: 10.1177/000456328302000503

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  5 in total

1.  The possible risk of bilirubin encephalopathy as predicted by plasma parameters in neonates with previous severe asphyxia.

Authors:  F Ebbesen; A Knudsen
Journal:  Eur J Pediatr       Date:  1992-12       Impact factor: 3.183

2.  Randomised trial of continuous nasogastric, bolus nasogastric, and transpyloric feeding in infants of birth weight under 1400 g.

Authors:  P D Macdonald; C H Skeoch; H Carse; F Dryburgh; L G Alroomi; P Galea; G Gettinby
Journal:  Arch Dis Child       Date:  1992-04       Impact factor: 3.791

3.  Development of aflatoxin B(1)-lysine adduct monoclonal antibody for human exposure studies.

Authors:  J S Wang; S Abubaker; X He; G Sun; P T Strickland; J D Groopman
Journal:  Appl Environ Microbiol       Date:  2001-06       Impact factor: 4.792

4.  Recovery of E. coli From Liver and Spleen of Broiler Birds and the Effects of Induced High Ammonia Level on Haematobiochemical Parameters and Its Amelioration by Different Modifiers.

Authors:  Muhammad Junaid Asif; Muhammad Tariq Javed; Aziz Ur Rehman; Farkhanda Manzoor; Muhammad Riaz; Muhammad Asif Javed; Shaza Zarnab; Ghulam Rasool
Journal:  Dose Response       Date:  2021-12-19       Impact factor: 2.658

5.  Arylesterase phenotype-specific positive association between arylesterase activity and cholinesterase specific activity in human serum.

Authors:  Yutaka Aoki; Kathy J Helzlsouer; Paul T Strickland
Journal:  Int J Environ Res Public Health       Date:  2014-01-27       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.