Literature DB >> 6650983

Transbronchial needle aspiration of peripheral masses.

D Shure, P F Fedullo.   

Abstract

Transbronchial needle aspiration through a flexible fiberoptic bronchoscope was performed on peripheral lung masses in 42 consecutive patients with bronchogenic carcinoma using a 20-gauge by 1-cm prototype needle. The aspiration was preceded by routine washings and brushings and followed by transbronchial forceps biopsy. Adding transbronchial needle aspiration to the standard combination of transbronchial biopsy, brush, and wash significantly improved the diagnostic yield (48 to 69%, p = 0.046). Considering only lesions 2 cm or greater in diameter, the combination of transbronchial needle aspiration, brush, and wash was superior to transbronchial biopsy, brush, and wash (76 versus 52%, p = 0.041). No complications occurred with either transbronchial needle aspiration or transbronchial biopsy, but transbronchial needle aspiration produced less bleeding than did transbronchial biopsy. We conclude that transbronchial needle aspiration of peripheral mass lesions is a safe procedure that can increase the diagnostic yield of flexible fiberoptic bronchoscopy.

Entities:  

Mesh:

Year:  1983        PMID: 6650983     DOI: 10.1164/arrd.1983.128.6.1090

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  13 in total

Review 1.  Conventional transbronchial needle aspiration in community practice.

Authors:  Elif Küpeli
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  Chest diseases: bronchoscopic needle aspiration.

Authors:  D Shure
Journal:  West J Med       Date:  1986-03

Review 3.  Diagnostic and therapeutic bronchoscopy.

Authors:  R S Tharratt; A Chan
Journal:  Clin Rev Allergy       Date:  1990 Summer-Fall

4.  Distinguishing Tumor from Associated Fibrosis to Increase Diagnostic Biopsy Yield with Polarization-Sensitive Optical Coherence Tomography.

Authors:  Lida P Hariri; David C Adams; Matthew B Applegate; Alyssa J Miller; Benjamin W Roop; Martin Villiger; Brett E Bouma; Melissa J Suter
Journal:  Clin Cancer Res       Date:  2019-06-07       Impact factor: 12.531

5.  Diagnosing lung carcinomas with optical coherence tomography.

Authors:  Lida P Hariri; Mari Mino-Kenudson; Michael Lanuti; Alyssa J Miller; Eugene J Mark; Melissa J Suter
Journal:  Ann Am Thorac Soc       Date:  2015-02

6.  Seeing beyond the bronchoscope to increase the diagnostic yield of bronchoscopic biopsy.

Authors:  Lida P Hariri; Martin Villiger; Matthew B Applegate; Mari Mino-Kenudson; Eugene J Mark; Brett E Bouma; Melissa J Suter
Journal:  Am J Respir Crit Care Med       Date:  2013-01-15       Impact factor: 21.405

7.  Pulmonary nodules 10 mm or less in diameter with ground-glass opacity component detected by high-resolution computed tomography have a high possibility of malignancy.

Authors:  Hyung-Eun Yoon; Kenjiro Fukuhara; Toshiya Michiura; Minoru Takada; Masami Imakita; Kentaro Nonaka; Kazuhiro Iwase
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-01

8.  Lung biopsy.

Authors:  J Macfarlane
Journal:  Br Med J (Clin Res Ed)       Date:  1985-01-12

9.  Toward the guidance of transbronchial biopsy: identifying pulmonary nodules with optical coherence tomography.

Authors:  Lida P Hariri; Mari Mino-Kenudson; Matthew B Applegate; Eugene J Mark; Guillermo J Tearney; Michael Lanuti; Colleen L Channick; Alex Chee; Melissa J Suter
Journal:  Chest       Date:  2013-10       Impact factor: 9.410

10.  Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions. Results of the AQuIRE Registry.

Authors:  David E Ost; Armin Ernst; Xiudong Lei; Kevin L Kovitz; Sadia Benzaquen; Javier Diaz-Mendoza; Sara Greenhill; Jennifer Toth; David Feller-Kopman; Jonathan Puchalski; Daniel Baram; Raj Karunakara; Carlos A Jimenez; Joshua J Filner; Rodolfo C Morice; George A Eapen; Gaetane C Michaud; Rosa M Estrada-Y-Martin; Samaan Rafeq; Horiana B Grosu; Cynthia Ray; Christopher R Gilbert; Lonny B Yarmus; Michael Simoff
Journal:  Am J Respir Crit Care Med       Date:  2016-01-01       Impact factor: 21.405

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.