Literature DB >> 6647739

The density and distribution of capillaries around a synovial cavity.

A D Knight, J R Levick.   

Abstract

The interpretation of trans-synovial fluxes requires a knowledge of the number of capillaries present around the joint cavity, and their depths below the surface of the joint lining. Measurements of capillary numbers, depths and dimensions were therefore carried out by light microscopy on synovial tissue sections from five rabbit knees. In addition the surface area of synovial tissue lining the joint was estimated, and the thickness of the synovium measured. Synovial capillary density was found to be uneven, with respect to both anatomical location in the joint cavity and depth below the synovial surface. The large area of synovium over areolar or adipose tissue was highly vascular (67000-83000 capillaries X cm-2 section; mean intercapillary distance 35-55 micron; 228-329 cm2 endothelium X cm-3 synovium). The small area of synovium over tendons was of very low vascularity (2000 capillaries X cm-2 section). From these data and a previous estimate of net filtration capacity, mean synovial endothelial conductivity was estimated as approximately 16 X 10(-7) cm X s-1 X mmHg-1. The depth distribution of the capillaries was extremely skewed, with a sharp peak at 6-11 micron depth. The rapid decay in capillary density at depths greater than 6-11 micron was partly due to an uneven density of capillaries within the synovium itself; and partly due to a lower density in subsynovial tissues. It was concluded that most synovium has a rich capillary bed which is very superficially located and that the depth of periarticular tissue which is effective in exchange processes with the joint cavity is less than 25 microns.

Entities:  

Mesh:

Year:  1983        PMID: 6647739     DOI: 10.1113/expphysiol.1983.sp002753

Source DB:  PubMed          Journal:  Q J Exp Physiol        ISSN: 0144-8757


  25 in total

Review 1.  Pharmacokinetics of nonsteroidal anti-inflammatory drugs in synovial fluid.

Authors:  R O Day; A J McLachlan; G G Graham; K M Williams
Journal:  Clin Pharmacokinet       Date:  1999-03       Impact factor: 6.447

2.  Microvascular distribution in normal human synovium.

Authors:  L S Wilkinson; J C Edwards
Journal:  J Anat       Date:  1989-12       Impact factor: 2.610

Review 3.  Hypoxia and inflammatory synovitis: observations and speculation.

Authors:  C R Stevens; R B Williams; A J Farrell; D R Blake
Journal:  Ann Rheum Dis       Date:  1991-02       Impact factor: 19.103

4.  Normal and healing ligament vascularity: a quantitative histological assessment in the adult rabbit medial collateral ligament.

Authors:  R C Bray; R M Rangayyan; C B Frank
Journal:  J Anat       Date:  1996-02       Impact factor: 2.610

5.  Cyclic movement stimulates hyaluronan secretion into the synovial cavity of rabbit joints.

Authors:  K R Ingram; A K T Wann; C K Angel; P J Coleman; J R Levick
Journal:  J Physiol       Date:  2008-01-17       Impact factor: 5.182

6.  Responses of bone and joint blood vessels in cats and rabbits to electrical stimulation of nerves supplying the knee.

Authors:  W R Ferrell; A Khoshbaten; W J Angerson
Journal:  J Physiol       Date:  1990-12       Impact factor: 5.182

7.  Spatial variation in sympathetic influences on the vasculature of the synovium and medial collateral ligament of the rabbit knee joint.

Authors:  J J McDougall; W R Ferrell; R C Bray
Journal:  J Physiol       Date:  1997-09-01       Impact factor: 5.182

8.  Morphology of surface synoviocytes in situ at normal and raised joint pressure, studied by scanning electron microscopy.

Authors:  J N McDonald; J R Levick
Journal:  Ann Rheum Dis       Date:  1988-03       Impact factor: 19.103

9.  Concentration polarization of hyaluronan on the surface of the synovial lining of infused joints.

Authors:  Y Lu; J R Levick; W Wang
Journal:  J Physiol       Date:  2004-10-07       Impact factor: 5.182

10.  Effect of depletion of glycosaminoglycans and non-collagenous proteins on interstitial hydraulic permeability in rabbit synovium.

Authors:  D Scott; P J Coleman; A Abiona; D E Ashhurst; R M Mason; J R Levick
Journal:  J Physiol       Date:  1998-09-01       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.