Literature DB >> 6642218

Intraocular diathermy coagulation.

J M Parel, R Machemer, G E O'Grady, G W Crock, I Nose.   

Abstract

Previously used transvitreal diathermy systems were found to be less than adequate. A new, safer 1.25 MHz medium frequency bipolar instrument is presented, which obviates most of the earlier drawbacks. Coagulation at the retinal surface can be obtained with as little as 0.15 J.

Entities:  

Mesh:

Year:  1983        PMID: 6642218     DOI: 10.1007/BF02171728

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  14 in total

1.  Optimized underwater diathermy for vitreous surgery.

Authors:  C L Schepens; F Delori; F J Rogers; I J Constable
Journal:  Ophthalmic Surg       Date:  1975

2.  An experimental investigation of the basic phenomena of retinopexy. I. Electrical impedance measurements.

Authors:  H A KNOLL
Journal:  Am J Ophthalmol       Date:  1958-04       Impact factor: 5.258

3.  A new concept for vitreous surgery. 4. Improvements in instrumentation and illumination.

Authors:  J M Parel; R Machemer; W Aumayr
Journal:  Am J Ophthalmol       Date:  1974-01       Impact factor: 5.258

4.  A transilluminator scleral marker.

Authors:  H DeGuillebon; C L Schepens
Journal:  Arch Ophthalmol       Date:  1971-09

5.  Bipolar coagulation in ophthalmic operations.

Authors:  S D McPherson
Journal:  Am J Ophthalmol       Date:  1972-05       Impact factor: 5.258

6.  Electrical impedance of ocular coats during diathermy applications. Voltage and time of application.

Authors:  H F deGuillebon; I Elzeneiny
Journal:  Arch Ophthalmol       Date:  1970-04

7.  Transvitreal radiofrequency diathermy.

Authors:  R Machemer
Journal:  Am J Ophthalmol       Date:  1977-02       Impact factor: 5.258

8.  A bipolar coaxial microprobe for safe transvitreal diathermy.

Authors:  J M Parel; G E O'Grady; R Machemer
Journal:  Arch Ophthalmol       Date:  1981-03

9.  Transvitreal radiofrequency diathermy.

Authors:  C L Schepens
Journal:  Am J Ophthalmol       Date:  1978-04       Impact factor: 5.258

10.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05
View more
  3 in total

1.  The development of pars plana vitrectomy: a personal account.

Authors:  R Machemer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-08       Impact factor: 3.117

2.  First-in-human study of the safety, effectiveness and ease of use of the intra-ocular diathermy forceps during vitrectomy.

Authors:  Koen van Overdam; Jerrel Pawiroredjo; Dinesh Jiawan; Sonia Manning
Journal:  Acta Ophthalmol       Date:  2019-05-14       Impact factor: 3.761

3.  Intra-ocular diathermy forceps.

Authors:  Koen A van Overdam; Emine Kilic; Robert M Verdijk; Sonia Manning
Journal:  Acta Ophthalmol       Date:  2017-12-02       Impact factor: 3.761

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.