Literature DB >> 6637236

Epidemic legionellosis in England and Wales 1979--1982.

C L Bartlett, L F Bibby.   

Abstract

National surveillance of legionnaires' disease in England and Wales identified 588 cases during the years 1979--1982. The majority of cases appeared to be sporadic but 32 clusters of two or more cases were recognised, 24 in association with hotels, seven with hospitals and one with a construction site. Reports (3 published and 3 unpublished) on the investigation and control of six outbreaks are reviewed. All six were found to be common source outbreaks; four hotel associated, one was nosocomial and one was associated with a construction site. Domestic water systems were implicated as sources in the four hotels and the hospital. The most effective control measure was found to be continuous chlorination of the water supply combined with raising the hot water temperature to 60 degrees C or more in the calorifier and at least 55 degrees C to a maximum of 60 degrees C at outlets. Raising hot water temperatures alone was not always completely successful as a control measure. Only in the construction site outbreak was a cooling water system shown to be the principal source of infection.

Entities:  

Mesh:

Year:  1983        PMID: 6637236

Source DB:  PubMed          Journal:  Zentralbl Bakteriol Mikrobiol Hyg A        ISSN: 0174-3031


  8 in total

1.  Evaluation of standardized scored inspections for Legionnaires' disease prevention, during the Athens 2004 Olympics.

Authors:  Ch Hadjichristodoulou; G Goutziana; V Mouchtouri; Ch Kapoula; A Konstantinidis; E Velonakis; A Vatopoulos; J Kremastinou
Journal:  Epidemiol Infect       Date:  2006-02-28       Impact factor: 2.451

Review 2.  Epidemiology, prevention and control of legionellosis: memorandum from a WHO meeting.

Authors: 
Journal:  Bull World Health Organ       Date:  1990       Impact factor: 9.408

3.  Balancing the risks: Legionella pneumophila pneumonia and tap water scalds in the home.

Authors:  R S Stanwick
Journal:  CMAJ       Date:  1986-12-01       Impact factor: 8.262

4.  Widespread Legionella pneumophila contamination of dental stations in a dental school without apparent human infection.

Authors:  B A Oppenheim; A M Sefton; O N Gill; J E Tyler; M C O'Mahony; J M Richards; P J Dennis; T G Harrison
Journal:  Epidemiol Infect       Date:  1987-08       Impact factor: 2.451

5.  The Stafford outbreak of Legionnaires' disease.

Authors:  M C O'Mahony; R E Stanwell-Smith; H E Tillett; D Harper; J G Hutchison; I D Farrell; D N Hutchinson; J V Lee; P J Dennis; H V Duggal
Journal:  Epidemiol Infect       Date:  1990-06       Impact factor: 2.451

6.  An outbreak of Legionnaires' disease in Gloucester.

Authors:  D A Hunt; K A Cartwright; M C Smith; J Middleton; C L Bartlett; J V Lee; P J Dennis; D Harper
Journal:  Epidemiol Infect       Date:  1991-08       Impact factor: 2.451

7.  Outbreak of legionnaires' disease from a cooling water system in a power station.

Authors:  S Morton; C L Bartlett; L F Bibby; D N Hutchinson; J V Dyer; P J Dennis
Journal:  Br J Ind Med       Date:  1986-09

Review 8.  Microbiological safety of drinking water: United States and global perspectives.

Authors:  T E Ford
Journal:  Environ Health Perspect       Date:  1999-02       Impact factor: 9.031

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.