An accurate recording system and its use in breath sounds spectral analysis.

G Charbonneau, J L Racineux, M Sudraud, E Tuchais.   

Abstract

An accurate recording system was set up and used for analyzing normal and asthmatic breath-sound features. Breath sounds are recorded at the trachea simultaneously with the airflow signal at 0.5- and 1-1/s levels. The study was carried out in the frequency domain using a fast-fourier transform (FFT). FFTs are taken on 1,024-sample blocks (one block = 200 ms) over a duration of about 20 s. Different characteristics of the spectra are calculated in the range 60-1,260 Hz for 11 normal and 10 asthmatic subjects. This allows the computation of an index that discriminates (P less than 0.0005) asthma cases from normal cases. Spectral features strongly depend on the flow rate both for normal and asthmatic subjects. Increasing the flow rate raises the high-frequency components of the spectra.

Entities:  

Mesh:

Year:  1983        PMID: 6629942     DOI: 10.1152/jappl.1983.55.4.1120

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  6 in total

Review 1.  The need for standards in recording and analysing respiratory sounds.

Authors:  M J Mussell
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

2.  Toolkit for lung sound analysis.

Authors:  T Rosqvist; E Paajanen; K Kallio; H M Rajala; T Katila; P Piirilä; P Malmberg; A Sovijärvi
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

3.  Evaluation of nocturnal bronchoconstriction by all night tracheal sound monitoring.

Authors:  C Lenclud; G Cuttitta; D Van Gansbeke; A Visconti; A Van Muylem; V Bellia; J C Yernault
Journal:  Thorax       Date:  1996-07       Impact factor: 9.139

4.  Lung sound crackle analysis using generalised time-frequency representations.

Authors:  H Pasika; D Pengelly
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

5.  Significant differences in flow standardised breath sound spectra in patients with chronic obstructive pulmonary disease, stable asthma, and healthy lungs.

Authors:  L P Malmberg; L Pesu; A R Sovijärvi
Journal:  Thorax       Date:  1995-12       Impact factor: 9.139

6.  Effect of air flow and flow transducer on tracheal breath sounds.

Authors:  M J Mussell; Y Nakazono; Y Miyamoto
Journal:  Med Biol Eng Comput       Date:  1990-11       Impact factor: 2.602

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.