Literature DB >> 6628007

Pulmonary function in mechanically-ventilated patients during 24-hour use of a hygroscopic condensor humidifier.

N R MacIntyre, H R Anderson, R M Silver, F R Schuler, R E Coleman.   

Abstract

Hygroscopic condensor humidifiers (HCH) are reportedly capable of humidifying even the driest of ventilator source gases with at least 30 mg H2O/liter of ventilation. To assess the adequacy of the HCH during mechanical ventilation, we studied 26 patients over a 72-hour period (alternating 24-hour periods of humidification by a conventional cascade and the HCH). In these patients, we found no significant difference in static lung compliance, airway resistance, PaO2, and PaCO2 on either system. Additionally, estimates of sputum volume (over a four-hour collection period) and clearance of aerosolized 99mTc labelled DTPA (in five of these patients) also showed no significant differences between the two systems. We conclude that the HCH is capable of supplying necessary heat and moisture to most mechanically-ventilated patients for at least a period of 24 hours.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6628007     DOI: 10.1378/chest.84.5.560

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Laboratory evaluation of heat-and-moisture exchangers.

Authors:  T Kugimiya; T G Phuc; K Numata
Journal:  J Anesth       Date:  1989-03-01       Impact factor: 2.078

Review 2.  Nosocomial pneumonia: epidemiology and infection control.

Authors:  D E Craven; K A Steger; L M Barat; R A Duncan
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

Review 3.  A review of the mechanisms and methods of humidification of inspired gases.

Authors:  M P Shelly; G M Lloyd; G R Park
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

4.  Necrotizing tracheobronchitis: a complication of high frequency jet ventilation.

Authors:  C Delafosse; J C Chevrolet; P Suter; J N Cox
Journal:  Virchows Arch A Pathol Anat Histopathol       Date:  1988

5.  Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance.

Authors:  M Chiaranda; L Verona; O Pinamonti; L Dominioni; G Minoja; G Conti
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

Review 6.  Heat and moisture exchangers (HMEs) and heated humidifiers (HHs) in adult critically ill patients: a systematic review, meta-analysis and meta-regression of randomized controlled trials.

Authors:  Maria Vargas; Davide Chiumello; Yuda Sutherasan; Lorenzo Ball; Antonio M Esquinas; Paolo Pelosi; Giuseppe Servillo
Journal:  Crit Care       Date:  2017-05-29       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.