Literature DB >> 6618950

Breath-by-breath alveolar gas exchange.

D Giezendanner, P Cerretelli, P E Di Prampero.   

Abstract

A method is described for breath-by-breath measurement of alveolar gas exchange corrected for changes of lung gas stores. In practice, the subject inspires from a spirometer, and each expired tidal volume is collected into a rubber bag placed inside a rigid box connected to the same spirometer. During the inspiration following any given expiration the bag is emptied by a vacuum pump. A computer monitors inspiratory and expiratory tidal volumes, drives four solenoid valves allowing appropriate operation of the system, and memorizes end-tidal gas fractions as well as mixed expired gas composition analyzed by mass spectrometer. Thus all variables for calculating alveolar gas exchange, based on the theory developed by Auchincloss et al. (J. Appl. Physiol. 21: 810-818, 1966), are obtained on a single-breath basis. Mean resting and steady-state exercise gas exchange data are equal to those obtained by conventional open-circuit measurements. Breathing rates up to 30 X min-1 can be followed. The breath-to-breath variability of O2 uptake at the alveolar level is less (25-35%) than that measured at the mouth as the difference between the inspired and expired volumes, both at rest and during exercise up to 0.7 of maximum O2 consumption.

Entities:  

Mesh:

Year:  1983        PMID: 6618950     DOI: 10.1152/jappl.1983.55.2.583

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  6 in total

Review 1.  New acquisitions in the assessment of breath-by-breath alveolar gas transfer in humans.

Authors:  M Cautero; P E di Prampero; C Capelli
Journal:  Eur J Appl Physiol       Date:  2003-09-27       Impact factor: 3.078

Review 2.  Slow VO₂ kinetics during moderate-intensity exercise as markers of lower metabolic stability and lower exercise tolerance.

Authors:  Bruno Grassi; Simone Porcelli; Desy Salvadego; Jerzy A Zoladz
Journal:  Eur J Appl Physiol       Date:  2010-09-07       Impact factor: 3.078

3.  Slow upward drift of VO2 during constant-load cycling in untrained subjects.

Authors:  G Camus; G Atchou; J C Bruckner; D Giezendanner; P E di Prampero
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988

4.  After effects of chronic hypoxia on VO2 kinetics and on O2 deficit and debt.

Authors:  U Boutellier; D Giezendanner; P Cerretelli; P E di Prampero
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1984

Review 5.  Algorithms, modelling and VO₂ kinetics.

Authors:  Carlo Capelli; Capelli Carlo; Michela Cautero; Cautero Michela; Silvia Pogliaghi; Pogliaghi Silvia
Journal:  Eur J Appl Physiol       Date:  2010-02-27       Impact factor: 3.078

Review 6.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.