Literature DB >> 6616774

Miscuffing: inappropriate blood pressure cuff application.

D M Manning, C Kuchirka, J Kaminski.   

Abstract

For the accurate indirect measurement of blood pressure (BP), the American Heart Association (AHA) now recommends that cuff size should be based solely on limb circumference. We studied prevailing cuffing habits and compared them with newly revised AHA guidelines. Monitoring our staff's cuff applications, we found that "miscuffing" occurred in 65 (32%) of 200 BP determinations on 167 unselected adult outpatients, including 61 (72%) of 85 readings taken on "nonstandard" size arms. Undercuffing large arms was the most frequent error, accounting for 84% of the miscuffings. Considering that miscuffing distorts BP readings by an average of 8.5 mm Hg systolic and 4.6 mm Hg diastolic, we can improve the accuracy of our BP determinations by remarking our cuffs and using the new AHA guidelines.

Mesh:

Year:  1983        PMID: 6616774     DOI: 10.1161/01.cir.68.4.763

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  22 in total

1.  Blood pressure monitoring technique impacts hypertension treatment.

Authors:  Gretchen M Ray; James J Nawarskas; Joe R Anderson
Journal:  J Gen Intern Med       Date:  2011-12-08       Impact factor: 5.128

2.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

3.  Out-of-Clinic Sympathetic Activity Is Increased in Patients With Masked Uncontrolled Hypertension.

Authors:  Mohammed Siddiqui; Eric K Judd; Byron C Jaeger; Hemal Bhatt; Tanja Dudenbostel; Bin Zhang; Lloyd J Edwards; Suzanne Oparil; David A Calhoun
Journal:  Hypertension       Date:  2019-01       Impact factor: 10.190

4.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

5.  White-Coat Effect Is Uncommon in Patients With Refractory Hypertension.

Authors:  Mohammed Siddiqui; Eric K Judd; Suzanne Oparil; David A Calhoun
Journal:  Hypertension       Date:  2017-07-10       Impact factor: 10.190

Review 6.  Utility of ambulatory blood pressure monitoring in children and adolescents.

Authors:  John W Graves; Mohammed Mahdi Althaf
Journal:  Pediatr Nephrol       Date:  2006-07-06       Impact factor: 3.714

7.  Agreement between large and small cuffs in sphygmomanometry: a quantitative assessment.

Authors:  Y Iyriboz; C M Hearon; K Edwards
Journal:  J Clin Monit       Date:  1994-03

8.  Masked Uncontrolled Hypertension Is Not Attributable to Medication Nonadherence.

Authors:  Mohammed Siddiqui; Eric K Judd; Tanja Dudenbostel; Bin Zhang; Pankaj Gupta; Maciej Tomaszewski; Prashanth Patel; Suzanne Oparil; David A Calhoun
Journal:  Hypertension       Date:  2019-07-22       Impact factor: 10.190

9.  Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement.

Authors:  Hemal Bhatt; Mohammed Siddiqui; Eric Judd; Suzanne Oparil; David Calhoun
Journal:  J Am Soc Hypertens       Date:  2016-03-30

10.  Reserpine Substantially Lowers Blood Pressure in Patients With Refractory Hypertension: A Proof-of-Concept Study.

Authors:  Mohammed Siddiqui; Hemal Bhatt; Eric K Judd; Suzanne Oparil; David A Calhoun
Journal:  Am J Hypertens       Date:  2020-08-04       Impact factor: 2.689

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.