Literature DB >> 6616002

Robust estimation in pulse fluorometry. A study of the method of moments and least squares.

I Isenberg.   

Abstract

Most laboratories use least-squares iterative reconvolution (LSIR) as a routine method for estimating decay parameters in pulse fluorometric data. It is shown here, however, that LSIR is very sensitive to small amounts of error in the data whenever two decays become too close to one another, or whenever analyses of three decays are attempted. In such cases, inferior methods of estimating integrals, small zero point shifts, or small errors in the measured exciting light will result in failures of least squares, where the method of moments, with moment index displacement and lambda invariance testing, will succeed. The method of moments is therefore robust with respect to such errors while least squares is not.

Mesh:

Year:  1983        PMID: 6616002      PMCID: PMC1329243          DOI: 10.1016/S0006-3495(83)84334-3

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  4 in total

1.  The use of standards in the analysis of fluorescence decay data.

Authors:  A Grinvald
Journal:  Anal Biochem       Date:  1976-09       Impact factor: 3.365

2.  On the analysis of fluorescence decay kinetics by the method of least-squares.

Authors:  A Grinvald; I Z Steinberg
Journal:  Anal Biochem       Date:  1974-06       Impact factor: 3.365

3.  Studies on the analysis of fluorescence decay data by the method of moments.

Authors:  I Isenberg; R D Dyson; R Hanson
Journal:  Biophys J       Date:  1973-10       Impact factor: 4.033

4.  Time-resolved fluorescence measurements.

Authors:  M G Badea; L Brand
Journal:  Methods Enzymol       Date:  1979       Impact factor: 1.600

  4 in total
  3 in total

1.  Padé-Laplace method for the analysis of time-resolved fluorescence decay curves.

Authors:  Z Bajzer; J C Sharp; S S Sedarous; F G Prendergast
Journal:  Eur Biophys J       Date:  1990       Impact factor: 1.733

2.  Padé-Laplace method for analysis of fluorescence intensity decay.

Authors:  Z Bajzer; A C Myers; S S Sedarous; F G Prendergast
Journal:  Biophys J       Date:  1989-07       Impact factor: 4.033

3.  Analysis of fluorescence decay kinetics from variable-frequency phase shift and modulation data.

Authors:  J R Lakowicz; G Laczko; H Cherek; E Gratton; M Limkeman
Journal:  Biophys J       Date:  1984-10       Impact factor: 4.033

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.