Abstract

Several agents are used as echocardiographic contrast agents, but their unreliability discourages routine clinical use. Studies from the early 1960s suggest that dilute hydrogen peroxide (H2O2) is a safe intravascular agent. Its use was evaluated in contrast echocardiography. To obtain dense opacification reliably, H2O2 (3%) was passed through a sterile 0.2 micron Millipore filter and diluted with heparinized saline solution to make a 0.1 to 0.2% solution. A drop of blood was withdrawn from an indwelling peripheral venous needle into a syringe containing 0.5 to 2.0 ml of the dilute H2O2 and the contents injected. Studies in dogs, normal adults and 36 patients with noncyanotic congenital and acquired cardiac disorders produced dense opacification with no complications. In vitro mixture of H2O2 (0.3%) with leukocyte-poor blood or plasma produced only a few microbubbles, while addition to whole blood or buffy coat produced many, suggesting a role for leukocyte peroxidase. H2O2 contrast echocardiography is simple, inexpensive, and reliably provides dense, sustained opacification. This study and previous studies suggest that intravenous injection of 0.2% H2O2 can be done safely. Great caution should be exercised in patients with severe pulmonary hypertension or large right-to-left shunts because little clinical experience with H2O2 is available.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6613886     DOI: 10.1016/0002-9149(83)90035-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  The development of echocardiography in China: the pioneering role of Xin-fang Wang.

Authors:  Tsung O Cheng
Journal:  Methodist Debakey Cardiovasc J       Date:  2012 Jul-Sep

2.  Left-sided contrast echocardiography with hydrogen peroxide--comparative effectiveness of pulmonary wedge injection by use of Swan-Ganz catheter and Cournand catheter.

Authors:  X F Wang; J E Wang; L S Cao; Y Z Huang; H Q Huang; Y Wu; Y B Deng
Journal:  J Tongji Med Univ       Date:  1988

3.  Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging.

Authors:  Emilia S Olson; Jahir Orozco; Zhe Wu; Christopher D Malone; Boemha Yi; Wei Gao; Mohammad Eghtedari; Joseph Wang; Robert F Mattrey
Journal:  Biomaterials       Date:  2013-08-16       Impact factor: 12.479

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.