Literature DB >> 6607178

1H NMR of intact muscle at 11 T.

C Arús, M Bárány, W M Westler, J L Markley.   

Abstract

1H NMR spectra of intact frog, and chicken skeletal muscles, were recorded at 470 MHz with the Plateau and Guéron pulse sequence for the suppression of water [(1982) J. Am. Chem. Soc. 104, 7310]. Only a few transients were required to resolve the resonances from the protons of muscle metabolites. The previously unobserved exchangeable protons of muscles were also recorded and thereby phosphocreatine and creatine could be measured simultaneously. During aging of dissected frog muscle, changes in levels of phosphocreatine, creatine and lactic acid, and the decrease in the intracellular pH were followed by 1H NMR.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6607178     DOI: 10.1016/0014-5793(84)80175-1

Source DB:  PubMed          Journal:  FEBS Lett        ISSN: 0014-5793            Impact factor:   4.124


  6 in total

1.  Michael Bárány: a recollection.

Authors:  Joseph M Chalovich
Journal:  J Muscle Res Cell Motil       Date:  2012-04-27       Impact factor: 2.698

2.  Spectroscopic applications of magnetic resonance to biomedical problems.

Authors:  M J Kushmerick
Journal:  Cardiovasc Intervent Radiol       Date:  1986       Impact factor: 2.740

3.  A technique for in vivo mapping of myocardial creatine kinase metabolism.

Authors:  Mohammad Haris; Anup Singh; Kejia Cai; Feliks Kogan; Jeremy McGarvey; Catherine Debrosse; Gerald A Zsido; Walter R T Witschey; Kevin Koomalsingh; James J Pilla; Julio A Chirinos; Victor A Ferrari; Joseph H Gorman; Hari Hariharan; Robert C Gorman; Ravinder Reddy
Journal:  Nat Med       Date:  2014-01-12       Impact factor: 53.440

4.  CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor.

Authors:  Kejia Cai; Anup Singh; Harish Poptani; Weiguo Li; Shaolin Yang; Yang Lu; Hari Hariharan; Xiaohong J Zhou; Ravinder Reddy
Journal:  NMR Biomed       Date:  2014-10-08       Impact factor: 4.044

5.  Creatine CEST MRI for Differentiating Gliomas with Different Degrees of Aggressiveness.

Authors:  Kejia Cai; Rong-Wen Tain; Xiaohong Joe Zhou; Frederick C Damen; Alessandro M Scotti; Hari Hariharan; Harish Poptani; Ravinder Reddy
Journal:  Mol Imaging Biol       Date:  2017-04       Impact factor: 3.488

6.  Brain pH Measurement Using AACID CEST MRI Incorporating the 2 ppm Amine Resonance.

Authors:  Mohammed Albatany; Susan Meakin; Robert Bartha
Journal:  Tomography       Date:  2022-03-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.