We have studied the effect of residential central air conditioning on indoor spore counts. The air of 6 pairs of homes (air-conditioned and non-air-conditioned) was sampled volumetrically 4 times daily for 3 consecutive days at 2-hr intervals in the kitchens, bedrooms, and basements with an Anderson sampler. Nearly simultaneous samples were taken outdoors at the same intervals. The total spore count was significantly lower (p less than 0.05) in the kitchens and bedrooms of air-conditined as compared to non-air-conditioned homes. Logarithmic conversion of the total spore count showed significant reduction in all indoor locations of air-conditioned homes. Multiple regression analysis revealed the lower relative humidity of air-conditioned homes to be associated with the lower spore counts. There was no difference in the percent concentration of the major genera within both types of homes. Since reducing the influx of outdoor spores decreases the total spore count without altering the relative concentration of the genera whereas filtration preferentially removes the larger spores, we conclude that the major mechanism in reducing spore counts in air-conditioned homes is the closed windows, although the lower relative humidity and perhaps filtration are also associated with lower spore counts.

Mesh:

Substances:

Year:  1978        PMID: 659736     DOI: 10.1016/0091-6749(78)90067-2

Source DB:  PubMed          Journal:  J Allergy Clin Immunol        ISSN: 0091-6749            Impact factor:   10.793


  4 in total

1.  Mold control.

Authors:  P P Kozak
Journal:  West J Med       Date:  1979-10

2.  Unveiling hidden energy poverty using the energy equity gap.

Authors:  Shuchen Cong; Destenie Nock; Yueming Lucy Qiu; Bo Xing
Journal:  Nat Commun       Date:  2022-05-04       Impact factor: 17.694

3.  In-hospital source of airborne Penicillium species spores.

Authors:  A J Streifel; P P Stevens; F S Rhame
Journal:  J Clin Microbiol       Date:  1987-01       Impact factor: 5.948

4.  Adverse health effects of particulate air pollution: modification by air conditioning.

Authors:  Michelle L Bell; Keita Ebisu; Roger D Peng; Francesca Dominici
Journal:  Epidemiology       Date:  2009-09       Impact factor: 4.822

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.