Literature DB >> 6576645

Maximum forces and deflections from orthodontic appliances.

C J Burstone, A J Goldberg.   

Abstract

The maximum bending moment of an orthodontic wire is an important parameter in the design and use of an orthodontic appliance. It is the wire property that determines how much force an appliance can deliver. A bending test which allows direct measurement of the maximum bending moment was developed. Data produced from this test are independent of wire length and configuration. The maximum bending moment, percent recovery, and maximum springback were determined for round and rectangular cross sections of stainless steel, nickel-titanium, and beta-titanium wires. The data suggest the need for more specifically defining maximum moment and maximum springback. Three maximum bending moments are described: Me, My, and Mult. My and Mult are clinically the most significant. Appliances that are required to have no permanent deformation must operate below My. Appliances that exhibit marked permanent deformation may be used in some applications and, if so, higher bending moments can be produced. In order of magnitude, the maximum bending moment at yield is largest in stainless steel, beta-titanium, and nickel-titanium for a given cross section. Nickel-titanium and beta-titanium have significantly larger springback than stainless steel determined at the moment at yield. Nickel-titanium did not follow the theoretical ratio between ultimate bending moment and the bending moment at yield, exhibiting a very large ratio. The study supports the hypothesis that most orthodontic appliances are activated in a range where both plastic and elastic behavior occurs; therefore, the use of yield strengths for calculation of force magnitude can lead to a significant error in predicting the forces delivered.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6576645     DOI: 10.1016/0002-9416(83)90173-2

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  7 in total

1.  [Relation of the activation force and deflection in various orthodontic springs (closing-loops)].

Authors:  G Schillai; K M Lehmann
Journal:  Fortschr Kieferorthop       Date:  1989-06

2.  [New wires and their force delivery--consequences for orthodontic therapy].

Authors:  H P Bantleon; H Droschl; K P Pfeiffer
Journal:  Fortschr Kieferorthop       Date:  1989-08

3.  Deflection test evaluation of different lots of the same nickel-titanium wire commercial brand.

Authors:  Murilo Gaby Neves; Fabrício Viana Pereira Lima; Júlio de Araújo Gurgel; Célia Regina Maio Pinzan-Vercelino; Fernanda Soares Rezende; Gustavo Antônio Martins Brandão
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb

4.  Mechanical properties and surface characterization of translucent composite wire following topical fluoride treatment.

Authors:  Shaza M Hammad; Essam E Al-Wakeel; El-Sayed Gad
Journal:  Angle Orthod       Date:  2011-06-30       Impact factor: 2.079

5.  Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires: a prospective clinical trial.

Authors:  Satpal S Sandhu; V Surendra Shetty; Subraya Mogra; Joseph Varghese; Jasleen Sandhu; Jagpreet S Sandhu
Journal:  Angle Orthod       Date:  2012-01-06       Impact factor: 2.079

6.  Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel.

Authors:  Ahmad Sheibaninia; Anahita Salehi; Armen Asatourian
Journal:  J Clin Exp Dent       Date:  2017-01-01

7.  The T-loop in details.

Authors:  Amanda Frizzo Viecilli; Maria Perpétua Mota Freitas
Journal:  Dental Press J Orthod       Date:  2018-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.