Results after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).

R Forman, W Beck, C N Barnard.   

Abstract

The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respectively. The thromboembolic rates were not different in the following two groups: (a) 238 patients receiving anticoagulants, and (b) 52 patients who had discontinued or who were not receiving anticoagulants. Four patients thrombosed their mitral prostheses. Another 8 per cent had class 3 symptoms after operation, which were attributed to myopathic or restrictive left ventricular dysfunction or other valvular disease.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 656234      PMCID: PMC483457          DOI: 10.1136/hrt.40.6.612

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  13 in total

1.  Living with prosthetic heart valves. Subsequent noncardiac operations and the risk of thromboembolism or hemorrhage.

Authors:  R E Katholi; S P Nolan; L B McGuire
Journal:  Am Heart J       Date:  1976-08       Impact factor: 4.749

Review 2.  Surgery for acquired valvular heart disease. 2.

Authors:  J W Kirklin; A D Pacifico
Journal:  N Engl J Med       Date:  1973-01-25       Impact factor: 91.245

3.  Mitral valve replacement with cloth-covered composite-seat prostheses. The case for early operation.

Authors:  L I Bonchek; R P Anderson; A Starr
Journal:  J Thorac Cardiovasc Surg       Date:  1974-01       Impact factor: 5.209

4.  A comparative study of ball and disc prostheses in mitral valve replacement.

Authors:  A Aris; A J Fast; A J Tector; R J Flemma; D Lepley
Journal:  J Thorac Cardiovasc Surg       Date:  1974-09       Impact factor: 5.209

5.  Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral.

Authors:  J Cleland; P J Molloy
Journal:  Thorax       Date:  1973-01       Impact factor: 9.139

6.  Myocardial dysfunction associated with valvular heart disease.

Authors:  F J Hildner; R P Javier; L S Cohen; P Samet; M J Nathan; W Z Yahr; J J Greenberg
Journal:  Am J Cardiol       Date:  1972-09       Impact factor: 2.778

7.  Functional classification of cardiac disease: a critique.

Authors:  A Selzer; K Cohn
Journal:  Am J Cardiol       Date:  1972-08       Impact factor: 2.778

8.  The use of single plane angiocardiograms for the calculation of left ventricular volume in man.

Authors:  H Sandler; H T Dodge
Journal:  Am Heart J       Date:  1968-03       Impact factor: 4.749

9.  The failure of hemodynamic improvement after valve replacement surgery. Etiology, diagnosis, and treatment.

Authors:  C R Peterson; R Herr; R V Crisera; A Starr; J D Bristow; H E Griswold
Journal:  Ann Intern Med       Date:  1967-01       Impact factor: 25.391

10.  Ball valve prostheses: current appraisal of late results.

Authors:  L I Bonchek; A Starr
Journal:  Am J Cardiol       Date:  1975-06       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.