Literature DB >> 656220

Long-term follow up of cardiac pacing threshold using a noninvasive method of measurement.

I D Starke.   

Abstract

Seventeen patients were followed up for a period ranging from 12 to 40 months after implantation of an Elema Vario pacemaker with an endocardial electrode. Two patients had a greater stimulation threshold beyond 6 months after implantation than the maximum threshold recorded before 6 months. One of these patients required replacement of the pacing system because of exit block. The 16 patients who retained their pacing systems showed, as a group, a statistically significant fall in stimulation threshold at 12 months after implantation despite continued pacing. These findings are important in relation to the occurrence and prediction of late exit block when long-life impulse generators are used.

Entities:  

Mesh:

Year:  1978        PMID: 656220      PMCID: PMC483440          DOI: 10.1136/hrt.40.5.530

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  10 in total

1.  CARDIAC STIMULATION THRESHOLD: CHRONIC STUDY.

Authors:  H M ALBERT; B A GLASS; B PITTMAN; P ROBICHAUX
Journal:  Ann N Y Acad Sci       Date:  1964-06-11       Impact factor: 5.691

2.  Tissue reaction to intracavitary electrodes: effect on duration and efficiency of unipolar pacing in patients with A-V block.

Authors:  C Contini; L Papi; A Pesola; A L'Abbate; G Magini; T D'Angelo; P Cinacchi; A Maseri; L Donato
Journal:  J Cardiovasc Surg (Torino)       Date:  1973 May-Jun       Impact factor: 1.888

3.  Transvenous, transmediastinal, and transthoracic ventricular pacing: a comparison after complete two-year follow-up.

Authors:  A S Brenner; G S Wagner; S T Anderson; R A Rosati; J J Morris
Journal:  Circulation       Date:  1974-03       Impact factor: 29.690

4.  Electrical threshold of the human heart.

Authors:  J G Davies; E Sowton
Journal:  Br Heart J       Date:  1966-03

5.  Chronic threshold measurement.

Authors:  T A Preston
Journal:  Ann Cardiol Angeiol (Paris)       Date:  1971 Jul-Aug

6.  Variation in pacing threshold. A study in patients with external pacemaker and unipolar endocardial electrode.

Authors:  H Grendahl; C G Schaanning
Journal:  Acta Med Scand       Date:  1970 Jan-Feb

7.  Assessment of cardiac pacemakers: pacemaker frontal plane vectors.

Authors:  G D Green
Journal:  Am Heart J       Date:  1971-01       Impact factor: 4.749

8.  Long-pulse stimuli for cardiac pacing.

Authors:  P Marchand; G G Jaros; I W Obel
Journal:  Ann N Y Acad Sci       Date:  1969-10-30       Impact factor: 5.691

9.  [Behavior of the intracardiac threshold of excitability during permanent electric stimulation].

Authors:  G Gadaleta; M Knippel; B Carù; C Ranzi
Journal:  Boll Soc Ital Cardiol       Date:  1971

10.  Permanent pacemaker treatment at Gentofte hospital. A follow-up study with special reference to transvenous electrode complications, generator longevity and control procedures.

Authors:  J Berning; B Larsen
Journal:  Acta Med Scand Suppl       Date:  1976
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.