Literature DB >> 655994

Heat acclimatization by a method utilizing microclimate cooling.

P C Schutte, G G Rogers, C H van Graan, N B Strydom.   

Abstract

A new approach to heat acclimatization has been shown to be feasible during laboratory experimentation. Wearing microclimate suits containing dry ice as the coolant, three groups of men were subjected to a moderate work rate in three different environments for 4 h/d for 8 d. Physiological responses on a subsequent heat tolerance test indicate that the group subjected to an environment of 32.0 degrees C W. B. and 33.5 degrees C D.B. were fully heat acclimatized. The 33/35 degrees C group were also well-acclimatized but developed dangerously high body temperatures during the first 2 d. Only partial acclimatization was achieved by the 31/33 degrees C group. The reason why the men acquire heat acclimatization while wearing the microclimate suits in a hot environment is probably that microclimate cooling does not prevent body temperature from rising--it only prevents it from rising excessively. It should be remembered that only one-third of the body is cooled while the rest shows the normal sweating response.

Entities:  

Mesh:

Year:  1978        PMID: 655994

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  1 in total

Review 1.  Heat acclimation: Gold mines and genes.

Authors:  Suzanne M Schneider
Journal:  Temperature (Austin)       Date:  2016-09-27
  1 in total