Literature DB >> 655823

[Biomechanical efficiency and biocompatibility of lubricating sprays PTFE or graphite (author's transl)].

W Mutschler, L Claes, W Mohr, P Hutzschenreuter.   

Abstract

The screws and plates used in operative treatment of fractures cause moments of friction between the bone screw head and the bone plate hole during the tightening of the screws. This results in hidden damage to the grinding metal surfaces, with the danger of erosion corrosion and in a reduction in the screw force. By covering the screw heads with the lubricating sprays PTFE or graphite friction was significantly reduced, the screw force increased by 40% and extensive damage to the surfaces avoided. Lubricating sprays or their extracts, in fetal calf serum or in dimethylsulfoxide, were added to fibroblast cultures. Toxicity was manifest as changes in the synthesis of DNA, as measured by autoradiography. Sprays or spray extracts in fetal calf serum did not inhibit cell proliferation. In vivo experiments in rats reflected the in vitro results, there being no evidence that toxic substances were released from the sprays by physiological solvents: There was a lack of histopathological changes in the inner organs and a local encapsulation of implants which was essentially like that in a teflon control group.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 655823     DOI: 10.1007/BF00378895

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  5 in total

1.  The foreign body reaction: a chronic inflammatory response.

Authors:  D L Coleman; R N King; J D Andrade
Journal:  J Biomed Mater Res       Date:  1974-09

2.  Reversible inhibition of protein synthesis in HeLa cells by dimethylsulfoxide.

Authors:  J L Saborio; G Koch
Journal:  J Biol Chem       Date:  1973-12-25       Impact factor: 5.157

3.  Effect of dimethyl sulfoxide on RNA synthesis in S-180 tumor cells.

Authors:  R F Hagemann
Journal:  Experientia       Date:  1969-12-15

4.  [Metallurgical studies on implants used in osteosyntetic surgery].

Authors:  F Brussatis; J Nonhoff
Journal:  Arch Orthop Unfallchir       Date:  1967

Review 5.  Pharmacologic and biochemical considerations of dimethyl sulfoxide.

Authors:  D C Wood; J Wood
Journal:  Ann N Y Acad Sci       Date:  1975-01-27       Impact factor: 5.691

  5 in total
  1 in total

Review 1.  Experimental testing of fracture fixation plates: A review.

Authors:  Shiling Zhang; Dharmesh Patel; Mark Brady; Sherri Gambill; Kanthan Theivendran; Subodh Deshmukh; John Swadener; Sarah Junaid; Laura Jane Leslie
Journal:  Proc Inst Mech Eng H       Date:  2022-08-03       Impact factor: 1.763

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.