Literature DB >> 6547939

Nitroaryl compounds as potential fluorescent probes for hypoxia. I. Chemical criteria and constraints.

P Wardman, E D Clarke, R J Hodgkiss, R W Middleton, J Parrick, M R Stratford.   

Abstract

Cellular reduction of nitroaryl compounds is efficiently inhibited by oxygen, and detection of products characteristic of reduction could form the basis for diagnostic tests for the presence of hypoxic cells in tumors. The criteria for suitable compounds include a high sensitivity and selectivity of detection response between oxic and hypoxic cells, which can be provided using fluorescence detection and suitable nitroaryl compounds which have very low fluorescence until reduced. Examples described include a nitroacridine and nitronaphthalimides. Although the intercalating ability of these ring systems lead to high sensitivity for detection of reduced metabolites in vitro by flow cytometry, poor bioavailability is an unwanted consequence of intercalation. The application of several model reducing systems for reduction of potential fluorescent probes for hypoxia is described, and the absorption and fluorescence spectral characteristics of other examples of structures which could form the basis for useful probes are outlined.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6547939     DOI: 10.1016/0360-3016(84)90346-8

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Hypoxia-selective, enzymatic conversion of 6-nitroquinoline into a fluorescent helicene: pyrido[3,2-f]quinolino[6,5-c]cinnoline 3-oxide.

Authors:  Anuruddha Rajapakse; Kent S Gates
Journal:  J Org Chem       Date:  2012-03-19       Impact factor: 4.354

2.  Enzymatic conversion of 6-nitroquinoline to the fluorophore 6-aminoquinoline selectively under hypoxic conditions.

Authors:  Anuruddha Rajapakse; Collette Linder; Ryan D Morrison; Ujjal Sarkar; Nathan D Leigh; Charles L Barnes; J Scott Daniels; Kent S Gates
Journal:  Chem Res Toxicol       Date:  2013-04-02       Impact factor: 3.739

3.  Versatile nitro-fluorophore as highly effective sensor for hypoxic tumor cells: design, imaging and evaluation.

Authors:  Min Dai; Weiping Zhu; Yufang Xu; Xuhong Qian; Yan Liu; Yi Xiao; Yin You
Journal:  J Fluoresc       Date:  2008-01-12       Impact factor: 2.217

4.  Role of oxygenation and vascularization in drug resistance.

Authors:  J Mattern; M Volm
Journal:  Cytotechnology       Date:  1998-09       Impact factor: 2.058

Review 5.  Oxygen Sensing, Hypoxia Tracing and in Vivo Imaging with Functional Metalloprobes for the Early Detection of Non-communicable Diseases.

Authors:  Vincenzo Mirabello; Fernando Cortezon-Tamarit; Sofia I Pascu
Journal:  Front Chem       Date:  2018-02-23       Impact factor: 5.221

6.  Hypoxia-triggered single molecule probe for high-contrast NIR II/PA tumor imaging and robust photothermal therapy.

Authors:  Xiaoqing Meng; Jiali Zhang; Zhihong Sun; Lihua Zhou; Guanjun Deng; Sanpeng Li; Wenjun Li; Ping Gong; Lintao Cai
Journal:  Theranostics       Date:  2018-11-15       Impact factor: 11.556

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.