The precise pressures and loads under 69 neuropathic feet have been measured during walking using a modified microprocessor-controlled optical system. Abnormally high pressures were demonstrated in 94% of feet with a history of foot ulceration, with pressures as high as 20-30 kg X cm-2 under the forefoot. All subjects were also studied using a new visco-elastic polymer material recently used for insole manufacture. A reduction in pressure was demonstrated that was proportional to peak pressure (linear regression line correlation coefficient of 0.91; P less than 0.001). We conclude that this material causes a significant reduction in the abnormally high pressures recorded under neuropathic feet, and should provide a useful insole for the management of patients at risk of neuropathic foot ulceration.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6546713     DOI: 10.2337/diacare.7.1.42

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  5 in total

1.  A randomized controlled trial comparing helium-neon laser therapy and infrared laser therapy in patients with diabetic foot ulcer.

Authors:  Sayed A Tantawy; Walid K Abdelbasset; Dalia M Kamel; Saud M Alrawaili
Journal:  Lasers Med Sci       Date:  2018-05-30       Impact factor: 3.161

Review 2.  Diabetic neuropathies. Current concepts in prevention and treatment.

Authors:  J D Ward
Journal:  Drugs       Date:  1986-09       Impact factor: 9.546

3.  Pedobarography as a clinical tool in the management of diabetic feet in New Zealand: a feasibility study.

Authors:  Jason K Gurney; Uwe G Kersting; Dieter Rosenbaum; Ajith Dissanayake; Steve York; Roger Grech; Anthony Ng; Bobbie Milne; James Stanley; Diana Sarfati
Journal:  J Foot Ankle Res       Date:  2017-06-09       Impact factor: 2.303

4.  Smart Insole Based on Flexi Force and Flex Sensor for Monitoring Different Body Postures.

Authors:  Rafique Ahmed Lakho; Zamir Ahmed Abro; Jun Chen; Rui Min
Journal:  Sensors (Basel)       Date:  2022-07-22       Impact factor: 3.847

5.  Evaluation of the IngVaL Pedobarography System for Monitoring of Walking Speed.

Authors:  Per Anders Rickard Hellstrom; Anna Åkerberg; Martin Ekström; Mia Folke
Journal:  Healthc Inform Res       Date:  2018-04-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.