Literature DB >> 6520058

A technique for long-term venous cannulation in rats.

D Koeslag, A S Humphreys, J C Russell.   

Abstract

We require repeated blood samples from rats over long periods in our studies on obese hyperlipemic animals and normal controls. Under our conditions of lipid adnormality and exercise previously reported techniques did not give long-term cannula patency. We have thus developed a technique using thromboresistant heparin-treated Silastic tubing and a mesh-stabilized metal cannula at the base of the skull. The tubing is inserted into the vena cava without occlusion and the tip lying in the region of the termination of the hepatic veins. The tubing exists from the abdomen through the incision and runs subcutaneously to a metal tube protruding from the skin. It is closed with a short length of polyethylene tubing folded over and secured with a tight Teflon sleeve. Heparinized saline is used to fill the cannula and flush it at biweekly intervals. The cannulas remain patent for long periods with 59% permitting withdrawal of blood at 120 days. Loss of function is random after 30 days when 100% were patent. A significant number remain functional at 200 days.

Entities:  

Mesh:

Year:  1984        PMID: 6520058     DOI: 10.1152/jappl.1984.57.5.1594

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  5 in total

1.  Long-term vascular access ports as a means of sedative administration in a rodent fMRI survival model.

Authors:  Patrick C Hettinger; Rupeng Li; Ji-Geng Yan; Hani S Matloub; Younghoon R Cho; Christopher P Pawela; Daniel B Rowe; James S Hyde
Journal:  J Neurosci Methods       Date:  2011-06-24       Impact factor: 2.390

2.  In vivo quantitative assessment of catheter patency in rats.

Authors:  Jun Yang; Jean-Michel I Maarek; Daniel P Holschneider
Journal:  Lab Anim       Date:  2005-07       Impact factor: 2.471

3.  Femoral arterial and venous catheterization for blood sampling, drug administration and conscious blood pressure and heart rate measurements.

Authors:  Brian Jespersen; Lauren Knupp; Carrie A Northcott
Journal:  J Vis Exp       Date:  2012-01-24       Impact factor: 1.355

4.  Pharmacokinetics of diltiazem and a new analogue, LR-A/113, in the conscious rat.

Authors:  R Bernasconi; S Caliari; R Latini; D Leopaldi; S Porzio; A Salimbeni
Journal:  Eur J Drug Metab Pharmacokinet       Date:  1992 Oct-Dec       Impact factor: 2.441

5.  Minimally Invasive Monitoring of Chronic Central Venous Catheter Patency in Mice Using Digital Subtraction Angiography (DSA).

Authors:  Giovanna Figueiredo; Teresa Fiebig; Stefanie Kirschner; Omid Nikoubashman; Lisa Kabelitz; Ahmed Othman; Andrea Nonn; Martin Kramer; Marc A Brockmann
Journal:  PLoS One       Date:  2015-06-22       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.