A new method for continuous intraoperative measurement of Harrington rod loading patterns.

A U Daniels, P Gemperline, A R Grahn, H K Dunn.   

Abstract

A new method has been developed for continuous intra-operative monitoring of bone and implant loading patterns in the operative correction of scoliosis using the Harrington distraction rod. The method incorporates a strain gauge instrumented, distal Harrington hook and similarly equipped Harrington operating instruments (outrigger and distractor). These latter instruments are used to calibrate the hook's response to bone loads under existing operative conditions. Alternative methods of monitoring loading patterns were explored and rejected because they were noncontinuous, more difficult to use, altered the mechanics of the system, or required more expensive components. The method established is being used to avoid bone rupture or rod damage while gaining maximum spinal correction and to determine the effect of auxiliary implant components on loading patterns.

Entities:  

Mesh:

Year:  1984        PMID: 6517404     DOI: 10.1007/bf02364308

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Force measurements during operative correction of spinal deformities.

Authors:  G G McBride; H K Dunn; A U Daniels
Journal:  Biomed Sci Instrum       Date:  1979 Apr 23-25

2.  The history and development of Harrington instrumentation.

Authors:  P R Harrington
Journal:  Clin Orthop Relat Res       Date:  1973-06       Impact factor: 4.176

3.  [Electronic pressure-gauge for the Harrington operation for scoliosis (author's transl)].

Authors:  K Zielke; B Pellin
Journal:  Z Orthop Ihre Grenzgeb       Date:  1973-04

4.  [Outrigger with dynamometer for Harrington's instrumentarium].

Authors:  K Zielke; B Pellin
Journal:  Z Orthop Ihre Grenzgeb       Date:  1972-04

5.  A force-indicating distractor for the Harrington-rod procedure.

Authors:  A Nachemson; G Elfström
Journal:  J Bone Joint Surg Am       Date:  1969-12       Impact factor: 5.284

6.  The introduction of force measurements guiding instrumental correction of scoliosis.

Authors:  C Hirsch; T Waugh
Journal:  Acta Orthop Scand       Date:  1968

7.  Intravital wireless telemetry of axial forces in Harrington distraction rods in patients with idiopathic scoliosis.

Authors:  A Nachemson; G Elfström
Journal:  J Bone Joint Surg Am       Date:  1971-04       Impact factor: 5.284

8.  A dynamometric outrigger for use in scoliosis surgery.

Authors:  R R Jacobs
Journal:  J Bone Joint Surg Am       Date:  1978-10       Impact factor: 5.284

9.  Intraoperative force measurements during correction of scoliosis.

Authors:  H K Dunn; A U Daniels; G G McBride
Journal:  Spine (Phila Pa 1976)       Date:  1982 Sep-Oct       Impact factor: 3.468

10.  Intravital measurements during instrumental correction of idiopathic scoliosis.

Authors:  T R Waugh
Journal:  Acta Orthop Scand       Date:  1966
  10 in total
  2 in total

1.  Continuous Rod Load Monitoring to Assess Spinal Fusion Status-Pilot In Vivo Data in Sheep.

Authors:  Markus Windolf; Maximilian Heumann; Viktor Varjas; Caroline Constant; Manuela Ernst; Robert Geoff Richards; Hans-Joachim Wilke; Lorin Michael Benneker
Journal:  Medicina (Kaunas)       Date:  2022-07-06       Impact factor: 2.948

2.  Smart implants in orthopedic surgery, improving patient outcomes: a review.

Authors:  Eric H Ledet; Benjamin Liddle; Katerina Kradinova; Sara Harper
Journal:  Innov Entrep Health       Date:  2018-08-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.