Literature DB >> 6512255

Bacterial contamination of floors and other surfaces in operating rooms: a five-year survey.

A Suzuki, Y Namba, M Matsuura, A Horisawa.   

Abstract

Bacterial contamination of floors and other surfaces in the operating suite has been investigated by contact impression plates during the past five years. Colony counts of the floors of operating rooms, cleaned with disinfectant, were 3.3 c.f.u./10 cm2; on the floors of semi-clean and dirty areas, cleaned with detergent, colony counts were 44.8 and 71.4 c.f.u./10 cm2 respectively. The highest colony counts of 487.4 c.f.u./10 cm2 were found in the dressing rooms, the floors of which were covered with carpets, cleaned with a vacuum cleaner. Mean bacterial numbers on surfaces of various equipment in operating rooms, cleaned with disinfectant, were 2.8 c.f.u./10 cm2. Bacterial numbers on surfaces decreased markedly from 253.2 to 11.9 c.f.u./10 cm2 following the use of disinfectant. Bacterial species found from various surfaces were mainly coagulase-negative staphylococci, derived from human beings. In the light of these findings the regular use of disinfectant for cleaning of the floors and other surfaces in operating rooms is advisable.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6512255      PMCID: PMC2129451          DOI: 10.1017/s002217240006513x

Source DB:  PubMed          Journal:  J Hyg (Lond)        ISSN: 0022-1724


  9 in total

1.  APPLICATION OF A SURFACE SAMPLING TECHNIC TO THE EVALUATION OF BACTERIOLOGICAL EFFECTIVENESS OF CERTAIN HOSPITAL HOUSEKEEPING PROCEDURES.

Authors:  D VESLEY; G S MICHAELSEN
Journal:  Health Lab Sci       Date:  1964-04

2.  Hospital cross-infection and dirty walls.

Authors:  W WYPKEMA; V G ALDER
Journal:  Lancet       Date:  1962-11-24       Impact factor: 79.321

3.  Contaminated areas in operating-theatres.

Authors:  P J Froud; V G Alder; W A Gillespie
Journal:  Lancet       Date:  1966-10-29       Impact factor: 79.321

4.  Why wash walls in hospital isolation rooms?

Authors:  N J Petersen; J H Marshall; D E Collins
Journal:  Health Lab Sci       Date:  1973-01

5.  Ward floors and other surfaces as reservoirs of hospital infection.

Authors:  G A Ayliffe; B J Collins; E J Lowbury; J R Babb; H A Lilly
Journal:  J Hyg (Lond)       Date:  1967-12

6.  Influence of operating room surface contamination on surgical wounds: a prospective study.

Authors:  D O Weber; J J Gooch; W R Wood; E M Britt; R O Kraft
Journal:  Arch Surg       Date:  1976-04

7.  Bacterial contamination in a modern operating suite, 2. Effect of a zoning system on contamination of floors and other surfaces.

Authors:  A Hambraeus; S Bengtsson; G Laurell
Journal:  J Hyg (Lond)       Date:  1978-02

8.  Bacterial contamination in a modern operating suite. 3. Importance of floor contamination as a source of airborne bacteria.

Authors:  A Hambraeus; S Bengtsson; G Laurell
Journal:  J Hyg (Lond)       Date:  1978-04

9.  Cleaning and disinfection of hospital floors.

Authors:  G A Ayliffe; B J Collins; E J Lowbury
Journal:  Br Med J       Date:  1966-08-20
  9 in total
  8 in total

1.  Evaluation of an automatic fogging disinfection unit.

Authors:  S Nakata; T Ikeda; H Nakatani; M Sakamoto; M Higashidutsumi; T Honda; A Kawayoshi; Y Iwamura
Journal:  Environ Health Prev Med       Date:  2001-10       Impact factor: 3.674

2.  Hamstring autografts are associated with a high rate of contamination in anterior cruciate ligament reconstruction.

Authors:  Abdulaziz Z Alomar; Saud M Alfayez; Ali M Somily
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-29       Impact factor: 4.342

Review 3.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

4.  Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

Authors:  Chalachew Genet; Gebre Kibru; Wondewosen Tsegaye
Journal:  Ethiop J Health Sci       Date:  2011-03

5.  A diversity of Antibiotic-resistant Staphylococcus spp. in a Public Transportation System.

Authors:  Pamela J Yeh; Dawn M Simon; Jess A Millar; H Forrest Alexander; Darleen Franklin
Journal:  Osong Public Health Res Perspect       Date:  2011-12

6.  The first microbial environment of infants born by C-section: the operating room microbes.

Authors:  Hakdong Shin; Zhiheng Pei; Keith A Martinez; Juana I Rivera-Vinas; Keimari Mendez; Humberto Cavallin; Maria G Dominguez-Bello
Journal:  Microbiome       Date:  2015-12-01       Impact factor: 14.650

7.  Antibiotic resistant airborne bacteria and their multidrug resistance pattern at University teaching referral Hospital in South Ethiopia.

Authors:  Fithamlak Bisetegen Solomon; Fiseha Wada Wadilo; Amsalu Amache Arota; Yishak Leka Abraham
Journal:  Ann Clin Microbiol Antimicrob       Date:  2017-04-12       Impact factor: 3.944

Review 8.  How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals.

Authors:  S J Dancer
Journal:  J Hosp Infect       Date:  2004-01       Impact factor: 3.926

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.