Literature DB >> 6508313

Role of stagnation and obstruction of water flow in isolation of Legionella pneumophila from hospital plumbing.

C A Ciesielski, M J Blaser, W L Wang.   

Abstract

The stagnation of water in two of four hospital hot-water storage tanks found to contain Legionella pneumophila was reduced by keeping the two tanks continually on-line for 1 year. L. pneumophila colony counts in these two tanks fell quickly to low levels, whereas the organisms persisted in the two tanks that were not in use. L. pneumophila continued to be isolated from 50 to 100% of the hospital showerheads which were sampled during this period. We also examined aerators and other hospital faucet fixtures which obstruct water flow. L. pneumophila was isolated from 22 of 30 faucet aerators and 2 of 16 vacuum breakers but not from 26 nonobstructed faucets or 6 backflow preventers. Over a 7-month period, after nine faucet aerators were sterilized, 10 of 60 surveillance cultures revealed L. pneumophila, despite the inability to isolate the organism from the potable-water tanks in use. These data suggest that prevention of stagnation in hot-water tanks may be effective in reducing L. pneumophila concentrations in potable-water systems serving high-risk populations. We have also shown that faucet aerators, by providing a surface for L. pneumophila to colonize, can become secondary reservoirs for the organism in hospital plumbing.

Entities:  

Mesh:

Year:  1984        PMID: 6508313      PMCID: PMC241662          DOI: 10.1128/aem.48.5.984-987.1984

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  17 in total

1.  Detection of Legionnaires disease bacteria by direct immunofluorescent staining.

Authors:  W B Cherry; B Pittman; P P Harris; G A Hebert; B M Thomason; L Thacker; R E Weaver
Journal:  J Clin Microbiol       Date:  1978-09       Impact factor: 5.948

2.  Survival of the Legionnaires' disease bacterium in water.

Authors:  P Skaliy; H V McEachern
Journal:  Ann Intern Med       Date:  1979-04       Impact factor: 25.391

3.  Legionella pneumophila in hospital hot water cylinders.

Authors:  S P Fischer-Hoch; M G Smith; J S Colbourne
Journal:  Lancet       Date:  1982-05-08       Impact factor: 79.321

4.  Legionella pneumophila in water plumbing systems.

Authors:  P J Dennis; J A Taylor; R B Fitzgeorge; C L Bartlett; G I Barrow
Journal:  Lancet       Date:  1982-04-24       Impact factor: 79.321

5.  Investigation and control of an outbreaks of legionnaires' disease in a district general hospital.

Authors:  S P Fisher-Hoch; C L Bartlett; J O Tobin; M B Gillett; A M Nelson; J E Pritchard; M G Smith; R A Swann; J M Talbot; J A Thomas
Journal:  Lancet       Date:  1981-04-25       Impact factor: 79.321

6.  Legionnaires' disease in a transplant unit: isolation of the causative agent from shower baths.

Authors:  J O Tobin; J Beare; M S Dunnill; S Fisher-Hoch; M French; R G Mitchell; P J Morris; M F Muers
Journal:  Lancet       Date:  1980-07-19       Impact factor: 79.321

7.  Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease.

Authors:  J Stout; V L Yu; R M Vickers; J Zuravleff; M Best; A Brown; R B Yee; R Wadowsky
Journal:  N Engl J Med       Date:  1982-02-25       Impact factor: 91.245

8.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures.

Authors:  R M Wadowsky; R B Yee; L Mezmar; E J Wing; J N Dowling
Journal:  Appl Environ Microbiol       Date:  1982-05       Impact factor: 4.792

9.  The faucet aerator - a source of pseudomonas infection.

Authors:  D F Cross; A Benchimol; E G Dimond
Journal:  N Engl J Med       Date:  1966-06-23       Impact factor: 91.245

10.  Potable water supply as the hospital reservoir for Pittsburgh pneumonia agent.

Authors:  J Stout; V L Yu; R M Vickers; J Shonnard
Journal:  Lancet       Date:  1982-02-27       Impact factor: 79.321

View more
  14 in total

1.  Risk factors for contamination of domestic hot water systems by legionellae.

Authors:  M Alary; J R Joly
Journal:  Appl Environ Microbiol       Date:  1991-08       Impact factor: 4.792

2.  Biofilm Composition and Threshold Concentration for Growth of Legionella pneumophila on Surfaces Exposed to Flowing Warm Tap Water without Disinfectant.

Authors:  Dick van der Kooij; Geo L Bakker; Ronald Italiaander; Harm R Veenendaal; Bart A Wullings
Journal:  Appl Environ Microbiol       Date:  2017-02-15       Impact factor: 4.792

3.  Protocol for sampling environmental sites for legionellae.

Authors:  J M Barbaree; G W Gorman; W T Martin; B S Fields; W E Morrill
Journal:  Appl Environ Microbiol       Date:  1987-07       Impact factor: 4.792

4.  The Legionella pneumophila collagen-like protein mediates sedimentation, autoaggregation, and pathogen-phagocyte interactions.

Authors:  Mena Abdel-Nour; Carla Duncan; Akriti Prashar; Chitong Rao; Christophe Ginevra; Sophie Jarraud; Donald E Low; Alexander W Ensminger; Mauricio R Terebiznik; Cyril Guyard
Journal:  Appl Environ Microbiol       Date:  2013-12-13       Impact factor: 4.792

Review 5.  Legionnaires disease: historical perspective.

Authors:  W C Winn
Journal:  Clin Microbiol Rev       Date:  1988-01       Impact factor: 26.132

6.  Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

Authors:  S J States; L F Conley; J M Kuchta; B M Oleck; M J Lipovich; R S Wolford; R M Wadowsky; A M McNamara; J L Sykora; G Keleti
Journal:  Appl Environ Microbiol       Date:  1987-05       Impact factor: 4.792

7.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

Review 8.  Opportunistic Premise Plumbing Pathogens: Increasingly Important Pathogens in Drinking Water.

Authors:  Joseph O Falkinham; Amy Pruden; Marc Edwards
Journal:  Pathogens       Date:  2015-06-09

Review 9.  Biofilms: the stronghold of Legionella pneumophila.

Authors:  Mena Abdel-Nour; Carla Duncan; Donald E Low; Cyril Guyard
Journal:  Int J Mol Sci       Date:  2013-10-31       Impact factor: 5.923

10.  Necessity and effect of combating Legionella pneumophila in municipal shower systems.

Authors:  Ragnhild Wiik; Anne Vatland Krøvel
Journal:  PLoS One       Date:  2014-12-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.