Literature DB >> 6499475

Detection of blood volume deficits through conjunctival oxygen tension monitoring.

E Abraham, R K Oye, M Smith.   

Abstract

Because acute blood loss may produce abnormal tissue perfusion and oxygenation before affecting blood pressure, we measured conjunctival (PcjO2) and arterial (PaO2) oxygen tensions and blood volume in 16 normotensive emergency department patients whose histories were consistent with significant blood loss. All eight patients with measured blood volume less than 85% of normal, as well as two euvolemic patients, had a PcjO2/PaO2 value of 0.57 or less, yielding a sensitivity of 100%, specificity of 75%, and positive predictive value of 80%. Lowering the cutoff point to 0.50 increased specificity and positive predictive value to 100% while reducing sensitivity to 88%. These results demonstrate that the PcjO2/PaO2 ratio is an early, sensitive, and specific indicator of significant blood volume deficit.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6499475     DOI: 10.1097/00003246-198411000-00001

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  8 in total

1.  Emergency medicine: conjunctival oximetry.

Authors:  E Abraham
Journal:  West J Med       Date:  1985-03

2.  Conjunctival oxygen tension and its relationship to arterial oxygen tension.

Authors:  K R Chapman; F L Liu; R M Watson; A S Rebuck
Journal:  J Clin Monit       Date:  1986-04

3.  Use of conjunctival oxygen monitoring in cardiac patients in the emergency unit.

Authors:  S Harding; S M Podolsky
Journal:  Arch Emerg Med       Date:  1988-12

4.  Tissue oximetry: an interim report.

Authors:  T K Hunt; J Rabkin; J A Jensen; K Jonsson; K von Smitten; W H Goodson
Journal:  World J Surg       Date:  1987-04       Impact factor: 3.352

5.  Bilateral conjunctival oxygen tension measurements.

Authors:  J Asmussen; S Gellett; H Pilegaard; F Gottrup
Journal:  J Clin Monit       Date:  1993-11

6.  [Conjunctival oxygen pressure in patients with acute cerebral infarct].

Authors:  U Staedt; E Holm; C S Kortsik; D L Heene
Journal:  Klin Wochenschr       Date:  1988-07-15

7.  Clinical evaluation of a multiparameter intra-arterial blood-gas sensor.

Authors:  E Abraham; T J Gallagher; S Fink
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

8.  Conjunctival oxygen monitoring in the initial assessment of trauma.

Authors:  J Heyworth
Journal:  Arch Emerg Med       Date:  1992-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.