Literature DB >> 6490464

Reproducibility and accuracy of airway area by acoustic reflection.

L J Brooks, R G Castile, G M Glass, N T Griscom, M E Wohl, J J Fredberg.   

Abstract

To determine the accuracy and reproducibility of measurements of airway area by acoustic reflection (AAAR) we made repeated measurements of tracheal areas in human volunteers, glass airway models, and excised canine tracheae. In 10 adult males, the mean ratio of tracheal AAAR to tracheal areas determined roentgenographically was not significantly different from one (1.06 +/- 0.13 SD). Within-run variability was 10 +/- 4% (CV), mean intrasubject day-to-day variability was 9 +/- 4% (CV). A custom-made mouthpiece is necessary for accurate measurements of AAAR. Mean variability related to differences in mouthpiece construction was 7 +/- 6% (CV). The effect of variations in upper airway and glottic sizes on tracheal AAAR measurements was investigated using glass airway models. In model studies, tracheal AAAR measurements were found to be independent of changes in proximal airway size for glottic apertures greater than or equal to 1 cm2 and upper airway areas less than or equal to 8 cm2. Tracheal area was, however, overestimated by 20% in the rigid-walled glass models. The effects of airway wall rigidity were qualitatively investigated by comparing acoustic and roentgenographic measurements of excised canine tracheae surrounded by either air or petroleum jelly. Differences in the accuracy of measurements of AAAR in vitro and in vivo are probably due to differences in airway wall inertance. These studies suggest that the measurement of AAAR yields an accurate and reproducible result that may be clinically useful for the noninvasive detection of changes in central airway geometry.

Entities:  

Mesh:

Year:  1984        PMID: 6490464     DOI: 10.1152/jappl.1984.57.3.777

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  7 in total

Review 1.  Available techniques for objective assessment of upper airway narrowing in snoring and sleep apnea.

Authors:  Christian E Faber; Luisa Grymer
Journal:  Sleep Breath       Date:  2003-06       Impact factor: 2.816

2.  Resonance mode analysis for volume estimation of asymmetric branching structures.

Authors:  D T Raphael; M A Epstein
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

3.  Effectiveness of Titratable Oral Appliance in Management of Moderate to Severe Obstructive Sleep Apnea-A Prospective Clinical Study with Acoustic Pharyngometry.

Authors:  Shiv Shankar Agarwal; Sanjeev Datana; I D Roy; Pushkar Andhare
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2021-11-16

Review 4.  Acoustic reflection: review and clinical applications for sleep-disordered breathing.

Authors:  John S Viviano
Journal:  Sleep Breath       Date:  2002-09       Impact factor: 2.816

5.  The Reliability of Oral and Pharyngeal Dimensions Captured with Acoustic Pharyngometry.

Authors:  Sonja M Molfenter
Journal:  Dysphagia       Date:  2016-06-04       Impact factor: 3.438

6.  The Strain on Airway Smooth Muscle During a Deep Inspiration to Total Lung Capacity.

Authors:  Ynuk Bossé
Journal:  J Eng Sci Med Diagn Ther       Date:  2019-01-18

7.  Acoustic pharyngometry: clinical and instrumental correlations in sleep disorders.

Authors:  Matteo Gelardi; Alessandro Maselli Del Giudice; Francesco Cariti; Michele Cassano; Aline Castelante Farras; Maria Luisa Fiorella; Pasquale Cassano
Journal:  Braz J Otorhinolaryngol       Date:  2007 Mar-Apr
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.