Literature DB >> 6480632

Kinematic total knee replacement.

F C Ewald, M A Jacobs, R E Miegel, P S Walker, R Poss, C B Sledge.   

Abstract

We reviewed 124 consecutive kinematic condylar total knee replacements (in ninety-one patients) at two to four years postoperatively. One hundred and eleven (90 per cent) were rated as good or excellent. The average active postoperative flexion was 106 degrees (range, 94 to 120 degrees). Twenty-two knees (18 per cent) had incomplete, non-progressive radiolucent lines, less than one millimeter in width, at the tibial bone-cement interface; these were considered insignificant. Restriction of stair-climbing ability in this series appeared to be a function of involvement of multiple joints rather than of patellar replacement, as the rheumatoid patients with resurfaced patellae performed the worst. The osteoarthritic patients with involvement of a single joint performed the best, regardless of whether the patella was resurfaced or not. When compared with a similar series of total knee replacements in which the tibial component was made entirely of plastic, less reaction at the bone-cement interface was found with the metal-backed kinematic tibial component. We suggest that this finding is clinical confirmation of in vitro studies that demonstrated the advantage of metal-backed tibial components. We concluded that this procedure, if meticulously performed, will give predictably good to excellent results with a low complication rate, a good postoperative range of motion, and a favorable-appearing bone-cement interface at two to four years.

Entities:  

Mesh:

Year:  1984        PMID: 6480632

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  15 in total

1.  Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design.

Authors:  Christopher L Peters; Patrick Mulkey; Jill Erickson; Michael B Anderson; Christopher E Pelt
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

2.  Reconstructive surgery of the lower extremity.

Authors:  R J Claridge
Journal:  Can Fam Physician       Date:  1990-03       Impact factor: 3.275

Review 3.  [Importance of the tibial slope in knee arthroplasty].

Authors:  Silvan Wittenberg; Ufuk Sentuerk; Lisa Renner; Claude Weynandt; Carsten F Perka; Clemens Gwinner
Journal:  Orthopade       Date:  2020-01       Impact factor: 1.087

4.  Cylindrical axis, not epicondyles, approximates perpendicular to knee axes.

Authors:  Clifton W Hancock; Mark J Winston; Joel M Bach; Bradley S Davidson; Donald G Eckhoff
Journal:  Clin Orthop Relat Res       Date:  2013-03-28       Impact factor: 4.176

5.  Full flexion after total knee replacement in rheumatoid arthritis.

Authors:  S Yoshino; H Shoji; M Komagamine
Journal:  Int Orthop       Date:  1990       Impact factor: 3.075

6.  Factors affecting the osteolysis around the components after posterior-stabilized total knee replacement arthroplasty.

Authors:  Chang Wan Kim; Seung Suk Seo; Jung Han Kim; Hyeong Joo Lee; Chang Rack Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

7.  The Ring total knee replacement.

Authors:  N Reissis; G Dendrinos; E Reissis; P A Ring
Journal:  Arch Orthop Trauma Surg       Date:  1988

8.  Functional adaptation of the human locomotor system to normal and abnormal loading patterns.

Authors:  R Poss
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

9.  Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.

Authors:  Eun-Kyoo Song; Hong-An Lim; Sang-Don Joo; Sung-Kyu Kim; Keun-Bae Lee; Jong-Keun Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

10.  Effect on patellar kinematics of the different patellar component designs in total knee arthroplasty: intraoperative measurement of dome type versus anatomic type.

Authors:  Takeshi Mochizuki; Koichiro Yano; Katsunori Ikari; Ryo Hiroshima; Ken Okazaki
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.