Literature DB >> 6473701

Development of dose equivalent meters based on microdosimetric principles.

J Booz.   

Abstract

In this paper, the employment of microdosimetric dose-equivalent meters in radiation protection is described considering the advantages of introducing microdosimetric methods into radiation protection, the technical suitability of such instruments for measuring dose equivalent, and finally technical requirements, constraints and solutions together with some examples of instruments and experimental results. The advantage of microdosimetric methods in radiation protection is illustrated with the evaluation of dose-mean quality factors in radiation fields of unknown composition and with the methods of evaluating neutron- and gamma-dose fractions. --It is shown that there is good correlation between dose-mean lineal energy, yD, and the ICRP quality factor. --Neutron- and gamma-dose fractions of unknown radiation fields can be evaluated with microdosimetric proportional counters without recurrence to other instruments and methods. The problems of separation are discussed. The technical suitability of microdosimetric instruments for measuring dose equivalent is discussed considering the energy response to neutrons and photons and the sensitivity in terms of dose-equivalent rate. Then, considering technical requirements, constraints, and solutions, the problems of the large dynamic range in LET, the large dynamic range in pulse rate, geometry of sensitive volume and electrodes, evaluation of dose-mean quality factors, calibration methods, and uncertainties are discussed.

Mesh:

Year:  1984        PMID: 6473701     DOI: 10.1007/bf01213218

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  6 in total

1.  A device for the measurement of dose as a function of specific ionization.

Authors:  H H ROSSI; W ROSENZWEIG
Journal:  Radiology       Date:  1955-03       Impact factor: 11.105

2.  The determination of LET spectra from energy-proportional pulse-height measurements. I. Track-length distributions in cavities.

Authors:  R D Birkhoff; J E Turner; V E Anderson; J M Feola; R N Hamm
Journal:  Health Phys       Date:  1970-01       Impact factor: 1.316

3.  Dose equivalent meter designs based on tissue equivalent proportional counters.

Authors:  J W Baum; A V Kuehner; R L Chase
Journal:  Health Phys       Date:  1970-12       Impact factor: 1.316

4.  Considerations on the random traversal of convex bodies and solutions for general cylinders.

Authors:  A M Kellerer
Journal:  Radiat Res       Date:  1971-08       Impact factor: 2.841

5.  Microdosimetric investigations on collimated fast-neutron beams for radiation therapy: I. Measurements of microdosimetric spectra and particle dose fractions in a water phantom for fast neutrons from 14 MeV deuterons on beryllium.

Authors:  J Fidorra; J Booz
Journal:  Phys Med Biol       Date:  1981-01       Impact factor: 3.609

6.  Nonlinear amplifier for use in mixed radiation rem responding radiation meters.

Authors:  J W Baum
Journal:  Health Phys       Date:  1967-07       Impact factor: 1.316

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.