Literature DB >> 6467998

The reproducibility of hemodynamic, electrocardiographic, and gas exchange data during treadmill exercise in patients with stable angina pectoris.

M Sullivan, F Genter, M Savvides, M Roberts, J Myers, V Froelicher.   

Abstract

Fourteen male patients with exercise test-induced angina and ST-segment depression underwent treadmill testing on three consecutive days to evaluate the reproducibility of certain treadmill variables. Computerized ST-segment analysis and expired gas analysis, including anaerobic threshold, were evaluated for reproducibility using an intra-class correlation coefficient analysis. Measured oxygen uptake at peak exercise displayed better reproducibility than total treadmill time, the onset of angina, and the gas exchange anaerobic threshold (ATGE). The double product, heart rate, and ST-segment displacement in lead X were found to be reproducible at peak exercise, the onset of angina, and the ATGE. The incorporation of gas exchange analysis can provide accurate physiologic determinants of exercise capacity in patients with angina pectoris. In addition, noninvasive estimates of myocardial oxygen demand and ischemia can be reproducibly determined. These findings have important implications for the design of studies evaluating the effects of an intervention on angina pectoris.

Entities:  

Mesh:

Year:  1984        PMID: 6467998     DOI: 10.1378/chest.86.3.375

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  11 in total

1.  Effect of sampling strategy on measures of VO2peak obtained using commercial breath-by-breath systems.

Authors:  David W Hill; Lindsay P Stephens; Sonja A Blumoff-Ross; David C Poole; Jimmy C Smith
Journal:  Eur J Appl Physiol       Date:  2003-05-17       Impact factor: 3.078

Review 2.  Exercise stress testing. An overview of current guidelines.

Authors:  S A Lear; A Brozic; J N Myers; A Ignaszewski
Journal:  Sports Med       Date:  1999-05       Impact factor: 11.136

3.  Assessment of exercise capacity in African patients with chronic heart failure using six minutes walk test.

Authors:  Rufus A Adedoyin; Samuel A Adeyanju; Michael O Balogun; Anthony O Akintomide; Rasaaq A Adebayo; Patience O Akinwusi; Taofeek O Awotidebe
Journal:  Int J Gen Med       Date:  2010-04-08

4.  Reliability of peak exercise testing in patients with heart failure with preserved ejection fraction.

Authors:  Jessica M Scott; Mark J Haykowsky; Joel Eggebeen; Timothy M Morgan; Peter H Brubaker; Dalane W Kitzman
Journal:  Am J Cardiol       Date:  2012-09-13       Impact factor: 2.778

5.  Functional capacity before and after cardioversion of atrial fibrillation: a controlled study.

Authors:  A T Gosselink; H J Crijns; M P van den Berg; S A van den Broek; H Hillege; M L Landsman; K I Lie
Journal:  Br Heart J       Date:  1994-08

6.  Reproducibility of peak oxygen uptake and other cardiopulmonary exercise testing parameters in patients with heart failure (from the Heart Failure and A Controlled Trial Investigating Outcomes of exercise traiNing).

Authors:  Daniel R Bensimhon; Eric S Leifer; Stephen J Ellis; Jerome L Fleg; Steven J Keteyian; Ileana L Piña; Dalane W Kitzman; Robert S McKelvie; William E Kraus; Daniel E Forman; Andrew J Kao; David J Whellan; Christopher M O'Connor; Stuart D Russell
Journal:  Am J Cardiol       Date:  2008-07-09       Impact factor: 2.778

Review 7.  How Accurate Is the Prediction of Maximal Oxygen Uptake with Treadmill Testing?

Authors:  John R Wicks; Neil B Oldridge
Journal:  PLoS One       Date:  2016-11-22       Impact factor: 3.240

8.  Multi-trait analysis for genome-wide association study of five psychiatric disorders.

Authors:  Yulu Wu; Hongbao Cao; Ancha Baranova; Hailiang Huang; Sheng Li; Lei Cai; Shuquan Rao; Minhan Dai; Min Xie; Yikai Dou; Qinjian Hao; Ling Zhu; Xiangrong Zhang; Yin Yao; Fuquan Zhang; Mingqing Xu; Qiang Wang
Journal:  Transl Psychiatry       Date:  2020-06-30       Impact factor: 6.222

Review 9.  Patients' needs, satisfaction, and health related quality of life: towards a comprehensive model.

Authors:  Mohsen Asadi-Lari; Marcello Tamburini; David Gray
Journal:  Health Qual Life Outcomes       Date:  2004-06-29       Impact factor: 3.186

10.  Observed change in peak oxygen consumption after aortic valve replacement and its predictors.

Authors:  Van Doan Tuyet Le; Gunnar Vagn Hagemann Jensen; Lars Kjøller-Hansen
Journal:  Open Heart       Date:  2016-05-26
View more