Literature DB >> 6465428

Carotid surgery without angiography.

J R Crew, M Dean, J M Johnson, D Knighton, T T Bashour, D Ellertson, E S Hanna.   

Abstract

We propose that circumstances exist in which angiography is not necessary or is unwarranted for the diagnosis and treatment of carotid arterial disease. High quality real-time B-mode ultrasonographic imaging, combined with both pulsed gated, and continuous wave Doppler analysis, shows a remarkably close correlation with the pathologic abnormality identified at operation. Scanning in the vascular laboratory not only provides quick, noninvasive, accurate assessment of the atherosclerotic disease, it can also provide plaque and blood flow detail not previously attainable. Carotid surgery can be effectively and safely performed in selected patients with the aid of ultrasonography and Doppler analysis without the need for invasive angiographic imaging.

Entities:  

Mesh:

Year:  1984        PMID: 6465428     DOI: 10.1016/0002-9610(84)90224-1

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  6 in total

Review 1.  Surgery offers no more than medical treatment in the management of transient ischaemic attack.

Authors:  J Thompson; P J McDonald; C D Johnson
Journal:  Ann R Coll Surg Engl       Date:  1990-03       Impact factor: 1.891

2.  The limitations of diagnosis of carotid occlusion by Doppler ultrasound.

Authors:  N M Bornstein; Z G Beloev; J W Norris
Journal:  Ann Surg       Date:  1988-03       Impact factor: 12.969

3.  Can clinical evaluation and noninvasive testing substitute for arteriography in the evaluation of carotid artery disease?

Authors:  W S Moore; S Ziomek; W J Quiñones-Baldrich; H I Machleder; R W Busuttil; J D Baker
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

4.  Accuracy of duplex versus angiography in patients undergoing carotid surgery.

Authors:  M J Boyle; A P Wolinski; R P Grimley
Journal:  J R Soc Med       Date:  1995-01       Impact factor: 5.344

5.  Doppler diagnosis of intracranial artery occlusive disorders.

Authors:  K F Lindegaard; S J Bakke; R Aaslid; H Nornes
Journal:  J Neurol Neurosurg Psychiatry       Date:  1986-05       Impact factor: 10.154

6.  Poor agreement in carotid artery stenosis detection by ultrasound between external offices and a vascular center.

Authors:  Georgiana-Aura Giurgea; Ilda Lilaj; Michael E Gschwandtner; Christian Margeta; Sonja Zehetmayer; Christoph Domenig; Oliver Schlager; Michael Schwameis; Renate Koppensteiner; Andrea Willfort-Ehringer
Journal:  Wien Klin Wochenschr       Date:  2012-11       Impact factor: 1.704

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.