Literature DB >> 6462608

Effect of varying size of scleral flap and corneal block on trabeculectomy.

R J Starita, R L Fellman, G L Spaeth, E M Poryzees.   

Abstract

Prospectively, 28 eyes of 23 patients undergoing trabeculectomy were divided into two groups. The first group received a large scleral flap (4 mm X 4 mm X 4 mm) and corneal block (3 mm X 3 mm). The second group received a small scleral flap (2 mm X 2 mm X 2 mm) and corneal block (1 mm X 1 mm). No other changes in technique were made. After a mean follow-up of 13 months, there was no significant difference in final intraocular pressure, visual acuity, or complication rates between groups.

Entities:  

Mesh:

Year:  1984        PMID: 6462608

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  5 in total

1.  Does the site of filtration influence the medium to long term intraocular pressure control following microtrabeculectomy in low risk eyes?

Authors:  A K Negi; A W Kiel; S A Vernon
Journal:  Br J Ophthalmol       Date:  2004-08       Impact factor: 4.638

2.  Modification of trabeculectomy to avoid postoperative hyphaema. The 'guarded anterior fistula' operation.

Authors:  A G Konstas; J L Jay
Journal:  Br J Ophthalmol       Date:  1992-06       Impact factor: 4.638

3.  Medium to long-term intraocular pressure control following small flap trabeculectomy (microtrabeculectomy) in relatively low risk eyes.

Authors:  S A Vernon; C Gorman; H J Zambarakji
Journal:  Br J Ophthalmol       Date:  1998-12       Impact factor: 4.638

4.  Topographic and keratometric astigmatism up to 1 year following small flap trabeculectomy (microtrabeculectomy).

Authors:  S A Vernon; H J Zambarakji; F Potgieter; J Evans; P B Chell
Journal:  Br J Ophthalmol       Date:  1999-07       Impact factor: 4.638

5.  The Influence of Scleral Flap Thickness, Shape, and Sutures on Intraocular Pressure (IOP) and Aqueous Humor Flow Direction in a Trabeculectomy Model.

Authors:  Amir Samsudin; Ian Eames; Steve Brocchini; Peng Tee Khaw
Journal:  J Glaucoma       Date:  2016-07       Impact factor: 2.503

  5 in total