Literature DB >> 6460725

Breath-by-breath VCO2 and VO2 required compensation for transport delay and dynamic response.

H Noguchi, Y Ogushi, I Yoshiya, N Itakura, H Yamabayashi.   

Abstract

Both transport delay (DELAY) and dynamic response (RESPONSE) of a mass spectrometer would theoretically result in considerable errors in the breath-by-breath calculation of VCO2 and VO2. However, curiously, the contribution of RESPONSE has been ignored. The purpose of this study is to quantify the error caused by RESPONSE. We found that RESPONSE of a mass spectrometer was regarded as a first-order response. We determined DELAY and time constant (T) of RESPONSE and compensated the on-line calculation for both DELAY and RESPONSE and for DELAY only. With T of 150 and 100 ms, deviations of VCO2 from the gas-collection method were 8 +/- 6 and 8 +/- 6 ml/min with compensation for both DELAY and RESPONSE, and 69 +/- 10 and 50 +/- 5 ml/min with compensation for DELAY only, respectively (mean +/- SD). Similar results were obtained with VO2. A computer simulation of error caused by RESPONSE disclosed that the error linearly increased with increasing T. We conclude that to be accurate within +/- 5% of the exact value, compensation should be made when T exceeds 25 ms.

Mesh:

Substances:

Year:  1982        PMID: 6460725     DOI: 10.1152/jappl.1982.52.1.79

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  20 in total

1.  A real-time algorithm to improve the response time of a clinical multigas analyser.

Authors:  L Wong; R Hamilton; E Palayiwa; C Hahn
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

2.  Laser-based absorption spectroscopy as a technique for rapid in-line analysis of respired gas concentrations of O2 and CO2.

Authors:  Beth Cummings; Michelle L Hamilton; Luca Ciaffoni; Timothy R Pragnell; Rob Peverall; Grant A D Ritchie; Gus Hancock; Peter A Robbins
Journal:  J Appl Physiol (1985)       Date:  2011-04-21

3.  Day-to-day changes in oxygen uptake kinetics at the onset of exercise during strenuous endurance training.

Authors:  T Yoshida; M Udo; T Ohmori; Y Matsumoto; T Uramoto; K Yamamoto
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

4.  Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO(2) Fick method.

Authors:  Philip J Peyton; Daniel Thompson; Paul Junor
Journal:  J Clin Monit Comput       Date:  2008-07-12       Impact factor: 2.502

5.  Effect of lung resection on blood lactate threshold in lung cancer patients.

Authors:  S Miyoshi; K Nakahara; Y Monden; Y Kawashima
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988

Review 6.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

7.  Rate of change of alveolar carbon dioxide and the control of ventilation during exercise.

Authors:  C J Allen; N L Jones
Journal:  J Physiol       Date:  1984-10       Impact factor: 5.182

8.  Noninvasive estimation of cardiac output with nonprescribed breathing.

Authors:  M E Cabrera; G M Saidel; M H Cohen
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

9.  Measurement of pulmonary CO2 elimination must exclude inspired CO2 measured at the capnometer sampling site.

Authors:  P H Breen; E R Serina; S J Barker
Journal:  J Clin Monit       Date:  1996-05

10.  A new method for breath-to-breath determination of oxygen flux across the alveolar membrane.

Authors:  J Grønlund
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1984
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.