Literature DB >> 6437680

Forearm arterial compliance: a new measure of arterial compliance?

D H Fitchett.   

Abstract

This study has investigated the origin of the pulsatile expansion of the forearm recorded by the amplification of the pulsatile signal derived from a mercury in rubber plethysmograph. Venous occlusion to pressures of 40 mmHg had no effect on the amplitude of the volume pulse, suggesting that the volume pulse originates in vessels distended by pressures above this level. Nitroglycerin in small doses (0.15 mg sublingual) increased the amplitude of the volume pulse without changing forearm vascular resistance, consistent with an arterial origin of the forearm volume pulse. The instantaneous relationship between the volume pulse and arterial pressure (forearm compliance) showed that nitroglycerin increased the volume pulse in association with a reduction in pulse pressure. As the volume pulse probably originates in the arterial system, the increase in forearm compliance is a measure of the increase in arterial compliance induced by nitroglycerin. Both the volume pulse and forearm compliance may be useful indicators of the effect of physiological and pharmacological interventions on the distensile properties of arteries.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6437680     DOI: 10.1093/cvr/18.11.651

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  4 in total

1.  Arterial-pulse oximetry loops: a new method of monitoring vascular tone.

Authors:  K H Shelley; W B Murray; D Chang
Journal:  J Clin Monit       Date:  1997-07

2.  Effects of long-term nicardipine treatment on hemodynamics of large arteries in essential hypertension.

Authors:  E Arosio; P Pancera; G Arcaro; F Priante; G Montesi; M Zannoni; A Lechi
Journal:  Cardiovasc Drugs Ther       Date:  1989-12       Impact factor: 3.727

3.  Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure.

Authors:  Anatoly S Karavaev; Anatoly S Borovik; Ekaterina I Borovkova; Eugeniya A Orlova; Margarita A Simonyan; Vladimir I Ponomarenko; Viktoriia V Skazkina; Vladimir I Gridnev; Boris P Bezruchko; Mikhail D Prokhorov; Anton R Kiselev
Journal:  Biophys J       Date:  2021-06-02       Impact factor: 3.699

4.  Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

Authors:  Mohamed Elgendi; Ian Norton; Matt Brearley; Derek Abbott; Dale Schuurmans
Journal:  PLoS One       Date:  2013-10-22       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.