Literature DB >> 6437421

Left ventricular platelet deposition after acute myocardial infarction. An attempt at quantification using blood pool subtracted indium-111 platelet scintigraphy.

F W Verheugt, J Lindenfeld, D L Kirch, P P Steele.   

Abstract

Since indium-111 platelet scintigraphy for the detection of left ventricular thrombosis often shows considerable non-specific blood pool activity a subtraction method using simultaneous technetium-99m blood pool scintigraphy was undertaken in 11 subjects with well documented remote myocardial infarction, who served as positive or negative controls, and in 18 consecutive patients with acute myocardial infarction. The results were compared with those of cross sectional echocardiography. Thirteen patients had transmural myocardial infarction and the calculated count per pixel in the left ventricle of the subtracted indium-111 platelet scintigram was (mean (SD)) 0.28(0.35), but five patients with subendocardial myocardial infarction had a mean count of 0.04(0.06). In seven patients with transmural myocardial infarction (two anterior and five inferior) left ventricular thrombosis was detected by indium-111 platelet scintigraphy but in only one of these by cross sectional echocardiography. None of the patients with subendocardial myocardial infarction had left ventricular thrombosis. Subtracted left ventricular counts correlated well with the visual results. It is concluded that left ventricular platelet sequestration after acute myocardial infarction may be quantified and precisely located and that quantitative longitudinal studies of the natural history and drug intervention are now possible.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6437421      PMCID: PMC481669          DOI: 10.1136/hrt.52.5.490

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  15 in total

Review 1.  Resolution problems in echocardiology: a source of interpretation errors.

Authors:  J Roelandt; W G van Dorp; N Bom; J D Laird; P G Hugenholtz
Journal:  Am J Cardiol       Date:  1976-02       Impact factor: 2.778

2.  Arterial embolectomy after acute myocardial infarction. A study of 31 patients.

Authors:  J E Thompson; A S Weston; L Sigler; P S Raut; D J Austin; R D Patman
Journal:  Ann Surg       Date:  1970-06       Impact factor: 12.969

3.  Oophorectomy in lymphangioleiomyomatosis and benign metastasizing leiomyoma.

Authors:  J A Winter
Journal:  N Engl J Med       Date:  1981-12-03       Impact factor: 91.245

4.  Diagnosis of left ventricular thrombi by two-dimensional echocardiography.

Authors:  R S Meltzer; D Guthaner; H Rakowski; R L Popp; R P Martin
Journal:  Br Heart J       Date:  1979-09

5.  Labeling of human platelets with [111In) 8-hydroxyquinoline.

Authors:  U Scheffel; M F Tsan; P A McIntyre
Journal:  J Nucl Med       Date:  1979-06       Impact factor: 10.057

6.  Incidence of left-ventricular thrombosis after acute transmural myocardial infarction. Serial evaluation by two-dimensional echocardiography.

Authors:  R W Asinger; F L Mikell; J Elsperger; M Hodges
Journal:  N Engl J Med       Date:  1981-08-06       Impact factor: 91.245

7.  Observations on detecting left ventricular thrombus with two dimensional echocardiography: emphasis on avoidance of false positive diagnoses.

Authors:  R W Asinger; F L Mikell; B Sharma; M Hodges
Journal:  Am J Cardiol       Date:  1981-01       Impact factor: 2.778

8.  Detection of left ventricular thrombus by two-dimensional echocardiography: sensitivity, specificity, and causes of uncertainty.

Authors:  J R Stratton; G W Lighty; A S Pearlman; J L Ritchie
Journal:  Circulation       Date:  1982-07       Impact factor: 29.690

9.  Comparison of Indium-111 platelet scintigraphy and two-dimensional echocardiography in the diagnosis of left ventricular thrombi.

Authors:  M D Ezekowitz; D A Wilson; E O Smith; R D Burow; L H Harrison; D E Parker; R C Elkins; M Peyton; F B Taylor
Journal:  N Engl J Med       Date:  1982-06-24       Impact factor: 91.245

10.  Left ventricular thrombi: in vivo detection by indium-111 platelet imaging and two dimensional echocardiography.

Authors:  J R Stratton; J L Ritchie; G W Hamilton; K E Hammermeister; L A Harker
Journal:  Am J Cardiol       Date:  1981-04       Impact factor: 2.778

View more
  1 in total

1.  Detection of ventricular thrombosis in acute myocardial infarction: value of indium-111 platelet scintigraphy in relation to two-dimensional echocardiography and clinical course.

Authors:  A J Küpper; F W Verheugt; W Jaarsma; E E van der Wall; M J van Eenige; W den Hollander; J P Roos
Journal:  Eur J Nucl Med       Date:  1986
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.