Literature DB >> 6435715

Haemoglobin saturation during incremental arm and leg exercise.

S K Powers, S Dodd, J Woodyard, R E Beadle, G Church.   

Abstract

There are few reports concerning the alterations in the percent of haemoglobin saturated with oxygen (%SO2) during non-steady state incremental exercise. Further, no data exist to describe the %SO2 changes during arm exercise. Therefore, the purpose of this study was made to assess the dynamic changes in %SO2 during incremental arm and leg work. Nine trained subjects (7 males and 2 females) performed incremental arm and leg exercise to exhaustion on an arm crank ergometer and a cycle ergometer, respectively. Ventilation and gas exchange measurements were obtained minute by minute via open circuit spirometry and changes in %SO2 were recorded via an ear oximeter. No significant difference (p greater than 0.05) existed between arm and leg work in end-tidal oxygen (PETO2), end-tidal carbon dioxide (PETCO2), or %SO2 when compared as a function of percent VO2 max. These results provide evidence that arterial O2 desaturation occurs in a similar fashion in both incremental arm and leg work with the greatest changes in %SO2 occurring at work rates greater than 70% VO2 max.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6435715      PMCID: PMC1859399          DOI: 10.1136/bjsm.18.3.212

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  11 in total

1.  Alveolo-arterial gas exchange at rest and during work at different 02 tensions.

Authors:  E ASMUSSEN; M NIELSEN
Journal:  Acta Physiol Scand       Date:  1960-10-31

2.  EFFECT OF LIGHT AND MODERATE EXERCISE ON ALVEOLAR-ARTERIAL O-2 TENSION DIFFERENCE IN MAN.

Authors:  C M HESSER; G MATELL
Journal:  Acta Physiol Scand       Date:  1965-03

3.  Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation.

Authors:  N A Saunders; A C Powles; A S Rebuck
Journal:  Am Rev Respir Dis       Date:  1976-06

4.  Continuous in vivo measurement of arterial oxygen saturation by oximetry.

Authors:  M R Flick; A J Block
Journal:  Heart Lung       Date:  1977 Nov-Dec       Impact factor: 2.210

5.  Clinical evaluation of a new ear oximeter.

Authors:  C Scoggin; L Nett; T L Petty
Journal:  Heart Lung       Date:  1977 Jan-Feb       Impact factor: 2.210

6.  Limitations to exercise capacity and endurance: pulmonary system.

Authors:  J Dempsey; P Hanson; D Pegelow; A Claremont; J Rankin
Journal:  Can J Appl Sport Sci       Date:  1982-03

7.  A new ear oximeter for assessment of exercise-induced arterial desaturation in patients with pulmonary diseases.

Authors:  H Poppius; A A Viljanen
Journal:  Scand J Respir Dis       Date:  1977-10

8.  Changes in arterial blood gas tensions during unsteady-state exercise.

Authors:  I H Young; A J Woolcock
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1978-01

9.  The accuracy and response characteristics of a simplified ear oximeter.

Authors:  K R Chapman; A D'Urzo; A S Rebuck
Journal:  Chest       Date:  1983-06       Impact factor: 9.410

10.  Hemoglobin affinity for oxygen during short-term exhaustive exercise.

Authors:  J P Klein; H V Forster; R D Stewart; A Wu
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1980-02
View more
  9 in total

Review 1.  Exercise-induced arterial hypoxaemia in athletes: a review.

Authors:  C Prefaut; F Durand; P Mucci; C Caillaud
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  The relationship between test protocol and the development of exercise-induced hypoxemia (EIH) in highly trained athletes.

Authors:  I L Lama; L A Wolski; K D Coutts; D C McKenzie
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

Review 3.  Exercise-induced hypoxaemia in highly trained athletes.

Authors:  S K Powers; J Williams
Journal:  Sports Med       Date:  1987 Jan-Feb       Impact factor: 11.136

4.  Incidence of exercise induced hypoxemia in elite endurance athletes at sea level.

Authors:  S K Powers; S Dodd; J Lawler; G Landry; M Kirtley; T McKnight; S Grinton
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988

Review 5.  Exercise-induced hypoxaemia in elite endurance athletes. Incidence, causes and impact on VO2max.

Authors:  S K Powers; D Martin; S Dodd
Journal:  Sports Med       Date:  1993-07       Impact factor: 11.136

6.  Exercise stimulus increases ventilation from maximal to supramaximal intensity.

Authors:  K I Norton; B Squires; L H Norton; N P Craig; P McGrath; T S Olds
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

7.  Exercise-induced hypoxemia in athletes: role of inadequate hyperventilation.

Authors:  S K Powers; D Martin; M Cicale; N Collop; D Huang; D Criswell
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

8.  Re-examination of the incidence of exercise-induced hypoxaemia in highly trained subjects.

Authors:  D D Brown; R G Knowlton; P B Sanjabi; B T Szurgot
Journal:  Br J Sports Med       Date:  1993-09       Impact factor: 13.800

9.  Cardiopulmonary function in bicycle racing over mountainous terrain at moderate altitude.

Authors:  K Terasawa; A Sakai; Y Yanagidaira; M Takeoka; K Asano; T Fujiwara; K Yanagisawa; O Kashimura; G Ueda
Journal:  Int J Biometeorol       Date:  1995-03       Impact factor: 3.787

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.