[New synthetic resorbable suture material in animal experiments and in clinical testing].

R Henke, U Kairies.   

Abstract

This new synthetic absorbable suture material has been tested in 90 animal experiments (Wistar rats) with regard to tissue reaction, absorption and breaking strength. The data obtained were compared with Polyglactin 910 (Vicryl), Catgut plain and polyester fibres. PDS-sutures produced only a minimal tissue reaction and were completely resorbed after 168 days. They retained 50% of its breaking strength until the 40th day after implantation.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6435336

Source DB:  PubMed          Journal:  Zentralbl Chir        ISSN: 0044-409X            Impact factor:   0.942


  1 in total

1.  [Animal experiment studies of suture material and suture technic of the stomach].

Authors:  M Raab; M Günther; E Godehardt; T Junginger
Journal:  Langenbecks Arch Chir       Date:  1985